LOCATION / CLEARANCES
When positioning the heater the main points governing the location are:
1.Flueing
2.Warm air distribution
This heater is not designed to be build in.
The flue is not designed to be positioned under floors, or below the level of the heater.
Flue
Terminal
Flue
Terminal
The flue terminal should be positioned away from flammable materials.
LP GAS
Flue Terminal
Do not flue into natural draught flues or fireplaces, this unit can only be used with one of the five types of Rinnai flue kits. Do not flue unit into other rooms. Flue terminal must be outside.
Flue may be positioned directly under opening windows, with a minimum clearance of 9" (230mm).
FLUE SIZES:
5 Flue lengths are available.
S flue walls 3"4 1/2" (75115mm)
Aflue walls 4 1/2"9 1/2" (115240mm)
Bflue walls 9 1/2"15 3/4" (240400mm)
Cflue walls 15 3/4"23 5/8" (400600mm)
Dflue walls 23 5/8"31 1/2" (600800mm)