SLEEVE AND MANIFOLD INSTALLATION
METHOD FOR STANDARD WALLS
1. Disassemble Manifold from Sleeve.
The flue consists of 3 parts, sleeve, inside connectors |
| Flanges |
| ||
and tube, outside terminal; |
|
|
|
| |
hard on outside terminal and inner connections, then |
|
|
|
| |
pull sleeve off outer terminal.) |
|
|
|
| |
NOTE: Clearance to combustibles for terminal |
| Sleeve |
| ||
assembly sleeve and flanges is 0". | Connection | Terminal | |||
|
| ||||
|
|
|
|
| |
2. Adjustment of Sleeve Length. |
|
|
|
| |
Measure wall thickness through previously drilled 3 1/8 | Do not extend |
|
|
| |
beyond red line |
|
|
| ||
(80mm) hole. |
|
|
| ||
Extension joint |
|
| |||
End of sleeve should protrude 3/16" 3/8" (5 10mm) | Extension | ||||
under plastic | |||||
from outside wall. Adjust sleeve length to wall |
|
|
|
| |
thickness plus 3/16" 3/8" (5 10mm). (Sleeve is |
|
|
| ("S" and "A" flues only) | |
threaded for adjustment.) Do not extend beyond red | Adjust length by turning sleeve. | ||||
line. | |||||
|
|
|
|
3. For S and A flue only.
Depending on flue set and wall thickness extension | A | B | C |
piece “C” may need to be removed. |
|
|
|
Cut plastic, remove extension, then follow instruction 2. |
|
|
|
This applies to “S” and “A” flues only. |
|
|
|
There is no extension on other flues, they can be fully |
|
| Remove extension at this |
adjusted by turning the threaded section. |
|
| |
"A" Flue only | point it necessary. |
4. Fixing Sleeve. |
|
| |
Fix to the wall, using the 3 screws provided. | "TOP" |
| |
NOTE: The flange is marked “TOP”, sleeve must be |
|
fitted with this mark Up. Check sleeve protrudes 3/16" |
|
3/8" (5 10mm) on the outside. | Fixing Screw |
| Don't remove green plastic covering from sleeve. |
– 20 –