INSTALLATION INSTRUCTIONS
INSTALLATION
IMPORTANT: REFER TO DATA BADGE AND TECHNICAL SPECIFICATION AT THE FRONT OF THE MANUAL TO ENSURE THE APPLIANCE IS CORRECTLY ADJUSTED FOR THE GAS TYPE AND CATEGORY APPLIED IN THE COUNTRY OF USE.
FOR DETAILS OF CHANGING BETWEEN GAS TYPES REFER TO SECTION 10, SERVICING, ‘REPLACING PARTS’.
1.SAFETY PRECAUTIONS
1.1For your own and other’s safety, you must install this appliance according to local and national codes of practice. Failure to install the stove correctly could lead to prosecution:
•Read these instructions before installing and using this stove.
1.2These instructions must be left intact with the user.
1.3Do not attempt to burn rubbish on this appliance.
1.4Keep all plastic bags away from young children.
1.5Do not place any object on or near to the appliance and allow adequate clearance above the appliance.
IF THE APPLIANCE IS EXTINGUISHED OR GOES OUT IN USE, WAIT 3 MINUTES BEFORE ATTEMPTING TO RELIGHT THE APPLIANCE.
2.installation of the appliance
1.1This appliance can be installed in four different ways:
1)Builder’s opening with a frame
2)Builder’s opening without a frame
3)Stud work with a frame
4)Stud work without a frame
Where no frame is used an edge kit is available to enable the installer to plaster to a finished edge: Kit No. 8727 CFFK01 for Studio 1 and 8727 CFFK02 for Studio 2
Options 1) and 2) above can be:
•top exit with a liner
•rear exit without a liner
1.2The Studio is supplied with a flue fixing plate to attach the flue to the appliance within the aperture, Diagram 1.
1
AR1010
When installing the appliance into a masonry chimney without a liner, it must be converted to a rear exit:
•Remove the two fixing screws securing the spigot assembly
•Slide the blanking plate into the guides
•Replace the two fixing screws, Diagram 2
2
AR2007
The flue must be in good condition and clear products of combustion, see Commissioning)
Option 3) and 4) must be fitted using the top exit only with rigid twin wall flue pipe.
THE APPLIANCE IS SUPPLIED WITH A WALL BOX CONTAINING THE BATTERIES AND TOUCH PAD. THIS MUST BE RECESSED INTO THE WALL WITH ACCESS FOR THE CABLES PRIOR TO FITTING THE APPLIANCE.
2.1Remove the appliance from the carton and discard all unnecessary packaging. Ensure no components are thrown away when unpacking.
2.2To access the controls and gas inlet:
•Remove the glass door, enamelled liners, burner and splitter plate. See Section 4
2.3The gas supply enters the fire through a silicon panel on the floor under the access panel, Diagram 3:
•Slit with a sharp knife before bringing through the supply pipe, Diagram 1