INSTALLATION INSTRUCTIONS
TECHNICAL SPECIFICATION
COVERING THE FOLLOWING MODELS:
STUDIO 1 CF: | STUDIO 2 CF: |
8700CFCHEC8701CFCHEC
P8700CFCHECP8701CFCHEC
Model | Gas CAT. | Gas Type | Working | Aeration | Injector | Gas Rate | Input kW (Gross) | Country | ||
|
|
| Pressure |
|
| m3/h |
|
|
| |
|
|
|
|
|
|
| High | Low |
| |
Studio 1 | 12H | Natural G20 | 20mbar | 6 x 10 | 390 | 0.657 | 6.9 | 4.0 | GB, IE | |
CF |
|
|
|
|
|
|
|
|
| |
Studio 1 | 13+ | Propane G31 | 37mbar | Open both | 185 | 0.257 | 6.9 | 4.0 | GB, IE | |
|
|
| ||||||||
Butane G30 | 29mbar | 0.197 | ||||||||
CF |
| sides |
|
|
|
| ||||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
Model | Gas | Gas Type | Working | Aeration | Injector | Gas Rate | Input kW (Gross) | Country | |
| CAT. |
| Pressure |
|
| m3/h |
|
|
|
|
|
|
|
|
|
| High | Low |
|
|
|
|
|
|
|
|
|
|
|
Studio 2 | 12H | Natural G20 | 20mbar | 9 x 15 | 530 | 0.791 | 8.3 | 4.2 | GB, IE |
CF |
|
|
| offset |
|
|
|
|
|
|
| Propane G31 | 37mbar | One side open |
| 0.312 |
|
|
|
Studio 2 | 13+ |
|
| + 10 x 16 | 225 |
| 8.3 | 4.2 | GB, IE |
CF |
|
|
|
|
|
|
|
|
|
| Butane G30 | 29mbar |
|
| 0.238 |
|
|
| |
| Open both |
|
|
|
| ||||
|
|
|
|
|
| ||||
|
|
|
| sides |
|
|
|
|
|
Studio 1 |
|
|
|
| Efficiency Class 2 - 70% | NOx Class 4 |
Studio 2 |
|
|
|
| Efficiency Class 2 - 78% | NOx Class 4 |
Weight | Fire Only | Profil | Bauhaus | Steel | Flue Size |
|
|
|
|
|
|
|
|
|
|
|
|
| TOP EXIT | REAR EXIT |
|
|
|
|
|
|
|
Studio 1 | 52 Kg | 3.6 Kg | 3.6Kg | 18.5Kg | 127mm ø | 178mm ø minimum |
Studio 2 | 60Kg | 4.6Kg | 4.6Kg | 21.8Kg | Gas Inlet Connection Size = 8mm ø | |
|
|
|
|
|
| |
|
|
|
|
| Minimum Flue Specification = T260/N2/0/D/1 | |
|
|
|
|
| Minimum Flue Temp = 220oC |
8