Stovax 8700CFCHEC, P8701CFCHEC Installation Instructions, 3.3STUD WORK INSTALLATION METHOD 2 EDGE

Models: 8701CFCHEC P8700CFCHEC P8701CFCHEC 8700CFCHEC

1 33
Download 33 pages 19.71 Kb
Page 16
Image 16
3.3STUD WORK INSTALLATION METHOD 2 (EDGE)

INSTALLATION INSTRUCTIONS

INSTALLATION

13

wall plate

AR1887

 

Because of the high temperatures this fire achieves, it is advisable to use marble slips or similar material between the appliance and the plasterboard

Never use a one-piece slip as expansion (even cracking) can occur. If a slip is used, longer screws are needed to secure the appliance.

Connect the flue system and gas services using the opening in the side of the chimney breast for access. After commissioning, finish the sides of the chimney breast, Diagram 14

14

AR1905

3.3STUD WORK INSTALLATION METHOD 2 (EDGE)

For this cool-wall Edge installation, the convected heat of the fire is channelled into the chimney cavity and vented at the top.

There is an optional Studio 1 Edge Fixing Kit available for installing the fire without a frame. CODE No. 8727CFFK01 (STUDIO 1) 8727CFFK02 (STUDIO 2).Using the fixing kit:

Fit the two side and bottom channels to the front flange of the fire, Diagram 15. There is a deliberate gap at the top for convected heat

15

This now determines the width of your two vertical stud work supports. The kit has been designed so that 12mm thick plasterboard can be taken to the three channels, Diagram 16

16

AR1934

Fix the edge of the vertical support flush to the edge of the channel

Build the stud work chimney breast to the desired size:

Ensure all clearances to combustible material are maintained, 3.1 above

17

AR1902

Fit non-combustible board to the stud work above the fire. This should extend a minimum of 400mm above the appliance.

Fit plasterboard to the remaining chimney breast front

Decide on the position for the wall box containing the batteries and wall switch

Mount it into the stud work chimney breast connecting up the wires from the fire, see Stud Work Installation with Frame for wiring detail on previous page

Connect the flue system and gas services using the opening in the side of the chimney breast for access

After commissioning, finish the sides of the chimney breast, Diagram 18

AR1912

16

Page 16
Image 16
Stovax P8701CFCHEC, P8700CFCHEC manual Installation Instructions, 3.3STUD WORK INSTALLATION METHOD 2 EDGE

FAQ

What material should be used between the appliance and plasterboard?

It is advisable to use marble slips or similar material to handle the high temperatures achieved by this fire.

What should be done after commissioning?

Finish the sides of the chimney breast as per Diagram 18AR191216.

What is the optional installation kit for cool-wall Edge installation?

The optional Studio 1 Edge Fixing Kit is available for installing the fire without a frame using CODE No.8727CFFK01 for Studio 1 and CODE No.8727CFFK02 for Studio 2.