Stovax P8701CFCHEC, P8700CFCHEC manual Installation Instructions, Site Requirements

Models: 8701CFCHEC P8700CFCHEC P8701CFCHEC 8700CFCHEC

1 33
Download 33 pages 19.71 Kb
Page 12
Image 12
Manual background

INSTALLATION INSTRUCTIONS

SITE REQUIREMENTS

5.2When the appliance is installed in a masonry chimney without a liner, there must be a minimum debris collection area, Diagram 1b

1b

AR2006

5.3DO NOT install onto a combustible wall; all combustible materials must be removed from the area shown in Diagram 1c.

1c

440 400

1160

not to scale

840

100960

AR1226

5.4A combustible shelf must be a minimum of 400mm above the top of the appliance. This is based on a 150mm deep shelf. For every extra 13mm of depth add 25mm above the 400mm from the top of the appliance, not the frame.

5.5A side wall must be a minimum of 300mm from the side of the appliance, not the frame.

12

Page 12
Image 12
Stovax P8701CFCHEC, P8700CFCHEC manual Installation Instructions, Site Requirements

FAQ

What are the minimum site requirements for installing a Stovax stove?

The appliance must be installed in a masonry chimney without a liner, with a minimum debris collection area as per Diagram 1b.

Can I install the stove onto a combustible wall?

No, all combustible materials must be removed from the area shown in Diagram 1c.

How far should a side wall be from the appliance?

A side wall must be a minimum of 300mm from the side of the appliance, not the frame.