Stovax 8700CFCHEC manual Servicing Instructions Fault Finding Charts, Ignition Functional Check

Models: 8701CFCHEC P8700CFCHEC P8701CFCHEC 8700CFCHEC

1 33
Download 33 pages 19.71 Kb
Page 24
Image 24
IGNITION FUNCTIONAL CHECK 2

IGNITION FUNCTIONAL CHECK 2

NO SPARK

Ensure there is no debris around the pilot assembly,

(e.g. soot etc.) which could short the spark, clean the area.

Consult the users instructions, retry.

FLAME FAILURE FUNCTIONAL CHECK 3

PILOT WILL NOT STAY LIT OR FIRE GOES OUT IN USE

Ensure there is no debris around the pilot assembly, (e.g. soot etc.) Check for fluff in the pilot aeration hole. See the Diagram in the Replacing Parts section.

24

 

 

 

No

 

 

From Ignition Fault

No

Is the valve being

Yes

 

 

 

Finding Chart 1

 

operated correctly?

 

 

Yes

 

 

 

 

Is the gap between

 

 

 

 

electrode and

 

 

 

 

thermocouple 4.0mm?

 

 

 

 

Yes

 

 

 

 

Has ignition lead

Yes

 

 

 

become detached or is

Correct and retry.

 

 

 

 

 

connection poor?

 

 

 

 

 

 

 

No

 

Check handset batteries are OK.

 

 

 

 

 

 

Remove the ignition lead

 

Replace if required. Check handset is

 

 

 

on manual. Check ON/OFF switch is

 

Yes

from electrode. With insulated

 

 

 

set to ON (I). Check batteries to the

 

pliers. Hold the tip 4.0mm from the

 

 

control unit. Replace if required.

 

 

pilot pipe work, is there a spark

 

 

 

 

Retry with handset and touch pad.

 

 

when the system is operated?

 

 

 

 

 

 

No

Has the ignition lead

 

become detached from the

Yes

control box?

 

 

 

 

No

Replace the lead, retry.

Replace the electrode

 

Replace the ignition

 

lead and retry.

 

 

 

 

 

Light the pilot using either the handset or the touch pad

 

 

 

 

 

 

 

 

 

No

 

Will pilot

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

With the pilot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

stay alight?

 

 

 

 

 

 

 

 

With the fire running

 

 

 

 

 

 

 

 

 

 

running is the gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

on full is the gas at

 

 

 

 

 

 

 

 

 

 

pressure as stated on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

 

 

 

 

No

the pressure stated

 

 

 

 

 

 

 

 

 

 

the data badge?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

on the data badge?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Problem is with the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pipe work or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fittings which lead

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to the fire. Correct

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

and retry.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Run for 3 mins,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

turn off, time interval

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

until mag unit shuts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

with a click. Is this

 

 

 

 

 

 

 

 

 

 

Is the pilot flame of the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

greater than 7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is thermocouple

 

 

 

 

 

seconds?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

correct length? Are the

 

 

 

 

 

 

 

connection good

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

thermocouple leads

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in back of valve?

 

 

 

 

 

 

No

 

 

 

 

 

 

 

 

 

 

damaged or loose in the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is the flue working?

 

 

interrupter block? Is the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON/OF switch in the ON

 

 

Yes

 

 

 

 

 

 

 

 

 

 

Tighten the

 

 

 

 

No

 

 

 

(I) position. See diagram ?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connection and retry.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace pilot unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rectify flue

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

Run for 3 mins, turn

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Will pilot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

stay alight?

 

 

 

 

 

 

 

 

 

off, time interval until

 

 

 

 

 

 

 

Yes

 

 

Change the pilot unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mag unit shuts with a

 

 

 

 

 

 

 

 

 

 

or damaged

 

 

 

 

 

 

 

 

 

 

No

 

 

 

No

 

click. Is this greater

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

than 7 seconds?

 

 

 

 

 

 

 

 

 

 

thermocouple leads

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Change mag

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

unit.

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYSTEM OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SERVICING INSTRUCTIONS FAULT FINDING CHARTS

Page 24
Image 24
Stovax 8700CFCHEC Servicing Instructions Fault Finding Charts, Ignition Functional Check, Flame Failure Functional Check

FAQ

What should I do if there is no spark during ignition?

Ensure there is no debris around the pilot assembly, such as soot, and consult the user instructions for further guidance.

How can I troubleshoot if the pilot will not stay lit or fire goes out in use?

Check for debris around the pilot assembly and the aeration hole. See the diagram in the Replacing Parts section for reference.

How do I ensure the gas pressure is correct for the stove?

Check that the gas pressure is as stated on the data badge. If not, rectify the flue and connections.

How do I replace the ignition lead?

If the ignition lead has become detached, replace it and retry the ignition.

What should I do if the pilot does not stay alight?

Change the pilot unit or check for any damaged thermocouple leads.

How can I ensure the flue is working properly?

Check for proper ventilation and ensure the flue is free from any obstructions.

How do I tighten the ON/OFF switch on the stove?

Ensure the ON/OFF switch is in the ON position and follow the diagram for reference.

What should I do if the system fails to produce a spark?

Consider changing the pilot unit and checking the thermocouple leads.

How can I rectify flue fittings which lead to the fire?

Check and replace any damaged or loose flue fittings.

How can I change the mag unit?

If necessary, change the mag unit and ensure it is functioning properly.