Overcurrent Prevention Device: This is a 3 amp. glass fuse found on P.C. board. Design to shut unit down in case of overcurrent. If fuse blows all indicator lamps will be “OFF”.
Power Outage Safety Device: This safety device cuts off gas passage and stops operation.
Local and state codes must be adhered to prior to installation.
Rinnai is continually updating and improving products therefore specifications are subject to change without prior notice.
| NG | LPG |
|
|
|
Minimum supply gas pressure | 3.5" (89mmH2O) | 8" (203mmH2O) |
|
|
|
Maximum supply gas pressure | 10.5" (267mmH2O) | 13.0" (330mmH2O) |
|
|
|
Manifold test pressure | Factory set | Factory set |
|
|
|
※See conversion for setting gas pressures.
*There are two 1/8" NPT test points for measuring differential pressure, one is located on the modulating gas valve, the other is located on the burner manifold. The minimum inlet gas supply pressure is for the purposes of input adjustment.
GENERAL INFORMATION
THIS SERIES HEATER IS DESIGN CERTIFIED BY CSA INTERNATIONAL AS A DIRECT VENT WALL FURNACE AND MUST BE INSTALLED ACCORDING TO THESE INSTRUCTIONS. ALTERATION OF THE ORIGINAL DESIGN INSTALLED OTHER THAN AS SHOWN IN THESE INSTRUCTIONS OR USED WITH A TYPE OF GAS NOT SHOWN ON THE RATING PLATE, IS THE RESPONSIBILITY OF THE PERSON AND COMPANY MARKING THE CHANGE.