MS
CONTROL DISPLAY UNIT
r bl bl bl bl bl bl bl bl bl |
| r bl bl |
47 48 49 50 51 52 53 54 55 56 | 57 58 59 60 61 62 63 64 65 | 66 67 68 |
H2 | H1 | I |
TF | W | r |
|
|
〔152℃〕OHS OHS
No 1〔130℃〕 No 2〔90℃〕
SW6, DIP SWITCH
SW1 FM, ADJUST SWITCH〔Hi〕
SW2 FM, ADJUST SWITCH〔Lo〕
SW3 POV, PRESSURE ADJUST SWITCH〔Hi〕
SW5, TEST SWITCH
SW4 POV, PRESSURE ADJUST SWITCH〔Lo〕
|
|
|
| TB |
|
| 1 2 3 |
|
|
|
| 4 | bk | TH |
| K | 5 | W | |
OFF | 6 |
|
| |
| 7 |
|
| |
1 2 3 4 |
| 8 | Y |
|
|
| 9 | Y |
|
CODE | COLOR |
bk | black |
bl | blue |
br | brown |
gr | green |
gr/y | green/yellow |
pl | purple |
r | red |
w | white |
MARK | PART NAME |
MS | MAIN SWITCH |
TH | THERMISTOR |
TF | THERMAL FUSE |
F | FUSE |
ER | ELECTRODE |
POV | MODULATING SOLENOID VALVE |
TR | TRANSFORMER |
FR | FLAME ROD |
– 36 –
A |
W W
H3
W W
OHS POV
No 3〔130℃〕
BL
gr/y
W
ER
W bk
44 46
H
4345 gy gy
bk 41 | 39 r |
| F |
| E |
|
|
W142 | 40 Y | bk | gy r |
| r | bk | W |
G |
| Y | |||||
| 31 32 33 | 23 24 25 26 | |||||
38 |
| 34 3536 | 2728 29 30 | ||||
37 |
| ||||||
|
| Y | or bl | Y | r | bl | W |
| SV1 |
|
| E1 |
|
|
|
|
|
| Y |
|
|
| |
| bk | bk |
|
|
|
|
|
gy | SV2 |
|
| Y |
|
|
|
or |
|
|
|
|
|
|
|
OH.TH |
12W
13W
|
|
|
| gr/y |
|
|
|
| gy |
|
| 〔F〕 |
| FM |
|
| 15 | W | |
D | B | C | 3A |
|
16 |
| |||
gy21 | 20 | 18 |
|
|
r |
|
|
|
|
r 22 | 19 | 17 |
|
|
|
|
| ||
|
| bk | W |
|
| gy gy |
TF | AC |
130℃� | 120V |
y | yellow |
gy | grey |
or | orange |
OH. TH | OVER HEAT THERMISTOR |
OHS1~3 | OVER HEAT SWITCH |
FM | CONVECTION FAN MOTOR |
SP | SPARKER |
SV1~2 | MAIN SOLENOID VALVE 1~2 |
BL | COMBUSTION FAN MOTOR |
TB | TERMINAL BLOCK |
bl |
r |
TR
gr
SP | FR |
|
If any of the original wire as supplied with the appliance must be replaced, it must be replaced with a wire of a least a 194°F temperature rating and number 18AWG or its equivalent. “CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.” Verify operation after servicing