Roberts Gorden TF-380, TF-350, TF-300, TF-120 Critical Hanger Placement, Typical Suspension Details

Models: TF-380 TF-250 TF-160 TF-200 TF-120 TF-300 TF-350

1 28
Download 28 pages 5.15 Kb
Page 20
Image 20
FIGURE 12: Critical Hanger Placement

TF-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL

FIGURE 12: Critical Hanger Placement

Typical Suspension Details

Beam Clamp

 

Rod (3/8")

24" min.* (9.5 mm)

(61 cm)

“X”*

 

Anchor Typical Suspension Details

Screw HookManual backgroundManual background (3/8") Manual background (9.5 mm)

Chain size 3/16" (4.7 mm)

Manual backgroundManual background minimum

“S” Hooks

Concrete Beam Locknut Wood Beam

Washers Manual background

Turnbuckle

* Allows for thermal expansion of system

Not Included

S Hooks

 

 

 

 

Side View

 

 

 

Hanger

Hanger

 

 

 

 

Reflector

 

 

 

 

Must Be Within 4" (10 cm)

Front View

 

45° Angle

Total Straight Length (both sides) or Length from U-Tube to U-Tube

Typical Expansion

Minimum “X” Length

in a Double "U" Layout

 

Each Side

 

 

 

 

0’ - 50’

 

±1” (3 cm)

 

12” (31 cm)

51’ - 60’

 

±2” (5 cm)

 

18” (46 cm)

61’ - 80’

 

±3” (8 cm)

 

24” (61 cm)

81’ - 100’

 

±4” (10 cm)

 

30" (76 cm)

101’ - 120’

 

±5” (13 cm)

 

36" (91 cm)

121’ - 140’

 

±6” (15 cm)

 

42" (107 cm)

141’ - 160’

 

±7” (18 cm)

 

48" (122 cm)

If the installation requires a shorter suspension length than the minimum listed, the suspension length may be reduced by 6" (16 cm). In this case, tube clamps MUST be used at the two farthest hangers on each side of the burner. See Page 15, Figure 13.

Description

Part Number

S-Hook

91907302

Tube/Reflector Hanger

03090100

14

Page 20
Image 20
Roberts Gorden TF-380, TF-350, TF-300, TF-120, TF-200, TF-160, TF-250 Critical Hanger Placement, Typical Suspension Details