Runco 1080p manual 1. Serial Commands continued, Serial Communications

Models: 1080p

1 114
Download 114 pages 1.54 Kb
Page 104
Image 104
Sets the value for output horizontal position

Serial Communications

Table 6-1. Serial Commands (continued)

Command

Parameter

Value

Description

(min/max)

Stored?

 

 

 

 

 

 

 

Input Position Commands

 

 

 

 

IHEIGHT

-100/100

YES

Sets the value for input height

 

 

 

 

IHEIGHT?

NA

NA

Returns input height value

 

 

 

 

IHPOS

-100/100

YES

Sets a value for horizontal input position

 

 

 

 

IHPOS?

NA

NA

Returns input horizontal position value

 

 

 

 

IVPOS

-100/100

YES

Sets a value for vertical input position

 

 

 

 

IVPOS?

NA

NA

Returns input vertical position value

 

 

 

 

IWIDTH

-100/100

YES

Sets the value for input width

 

 

 

 

IWIDTH?

NA

NA

Returns input horizontal width value

 

 

 

 

OVERSCAN

0/10

YES

Sets the overscan percentage

 

 

 

 

OVERSCAN?

NA

NA

Returns overscan percentage

 

 

 

 

 

Output Shift Commands

 

 

 

 

OHEIGHT

-100/100

YES

Sets the value for output height

 

 

 

 

OHEIGHT?

NA

NA

Returns output height value

 

 

 

 

OHPOS

-100/100

YES

Sets the value for output horizontal position

 

 

 

 

OHPOS?

NA

NA

Returns output horizontal position value

 

 

 

 

OVPOS

-100/100

YES

Sets the value for output vertical position

 

 

 

 

OVPOS?

NA

NA

Returns output vertical position value

 

 

 

 

OWIDTH

-100/100

YES

Sets the value for output width

 

 

 

 

OWIDTH?

NA

NA

Returns output horizontal width value

 

 

 

 

92

Runco VX-44d/-55d Owner’s Operating Manual

Page 104
Image 104
Runco 1080p manual 1. Serial Commands continued, Serial Communications, Sets the value for output horizontal position