Maintenance and Troubleshooting

13.Press ENTER to accept the change. This adds the new lamp serial number to the Lamp History menu and resets the Lamp Hours timer to “0.” Lamp Mode and Lamp Limit remain as they were for the previous lamp and can be changed at any time.

Lamp Adjust

Lamp Hours

147

Lamp S/N

123456789

1. Lamp Message

2.Lamp Limit 1000

3. Lamp Mode Power

4.Power 500

5.

Intensity

0

6.

RVR

3

7.

Lamp History

 

8.Change Lamp

9. Reserved

Figure 5-5. Recording the Serial Number of a New Lamp

Always record the serial number of a new lamp. Do this only if you

Note have just installed a new lamp. This will ensure that the lamp timer is not reset on an old lamp and that the number of hours logged on the lamp is accurate.

Whenever you replace the lamp – or more often if the projector is installed in an extremely Filter Replacement

dusty environment – you should also replace the two filters located at the front and right

side of the projector.

 

1. Loosen the six screws holding right side filter access

Side Filter Access Cover

panel in place. Then, remove the panel.

 

2. Loosen the two screws holding front filter access

Front Filter Access Cover

panel in place. Then, remove the panel.

 

3.Pull the filters out of the projector and discard. Do not reuse filters.

4.Insert the new filters with the wired side in.

5.Replace the filter access panels and tighten the screws to secure them.

Runco VX-44d/-55d Owner’s Operating Manual

81

Page 93
Image 93
Runco 1080p manual 147, Lamp S/N, Lamp Message Lamp Limit Lamp Mode Power Intensity, Rvr, Change Lamp