Serial Communications

Table 6-1. Serial Commands (continued)

Command

Parameter

 

Value

Description

(min/max)

 

Stored?

 

 

 

 

 

 

 

 

 

 

Input Position Commands

 

 

 

 

 

IHEIGHT

-100/100

 

YES

Sets the value for input height

 

 

 

 

 

IHEIGHT?

NA

 

NA

Returns input height value

 

 

 

 

 

IHPOS

-100/100

 

YES

Sets a value for horizontal input position

 

 

 

 

 

IHPOS?

NA

 

NA

Returns input horizontal position value

 

 

 

 

 

IVPOS

-100/100

 

YES

Sets a value for vertical input position

 

 

 

 

 

IVPOS?

NA

 

NA

Returns input vertical position value

 

 

 

 

 

IWIDTH

-100/100

 

YES

Sets the value for input width

 

 

 

 

 

IWIDTH?

NA

 

NA

Returns input horizontal width value

 

 

 

 

 

OVERSCAN

0/10

 

YES

Sets the overscan percentage

 

 

 

 

 

OVERSCAN?

NA

 

NA

Returns overscan percentage

 

 

 

 

 

 

 

Output Shift Commands

 

 

 

 

 

OHEIGHT

-100/100

 

YES

Sets the value for output height

 

 

 

 

 

OHEIGHT?

NA

 

NA

Returns output height value

 

 

 

 

 

OHPOS

-100/100

 

YES

Sets the value for output horizontal position

 

 

 

 

 

OHPOS?

NA

 

NA

Returns output horizontal position value

 

 

 

 

 

OVPOS

-100/100

 

YES

Sets the value for output vertical position

 

 

 

 

 

OVPOS?

NA

 

NA

Returns output vertical position value

 

 

 

 

 

OWIDTH

-100/100

 

YES

Sets the value for output width

 

 

 

 

 

OWIDTH?

NA

 

NA

Returns output horizontal width value

 

 

 

 

 

52 Runco PL-43DHD and PL-50DHD Owner’s Operating Manual