6. Serial Communications

To interface the PlasmaWall with a home theater automation/control system or a PC running terminal emulation software, connect it to the RS-232 output of the DHD Controller as shown in Figure 3-3.Connect your control system or PC to the RS-232 input of the DHD Controller as shown in Figure 3-9.

Configure the RS-232 controller or PC serial port as follows: no parity, eight (8) data bits, one (1) stop bit and no flow control. Set the baud rate to 19200, to match that of the DHD Controller RS-232 port.

Serial commands to the DHD Controller take the following form:

Commands are not case-sensitive.

For a single command that takes no parameters, type the command followed by a carriage return; for example, to set the aspect ratio to Letterbox, type

LETTERBOX <Enter>.

For a single command that takes a parameter, type the command, a space or a comma and the desired value followed by a carriage return; for example, to set the brightness to -10, type BRIGHTNESS -10<Enter> or

BRIGHTNESS,-10 <Enter>.

You can also send a string of multiple commands on a single line, separated by commas. For example, COMPOSITE,BRIGHTNESS 100,ANAMORPHIC <Enter> switches to the Composite video input, sets the brightness to 100 and sets the aspect ratio to Anamorphic. Command strings can be up to 255 characters long.

Avoid combining the ON or POWER 1 commands with other commands Note on a single line. After sending ON or POWER 1, allow at least 15

seconds for the DHD Controller to power up. Once it does, it will accept and properly execute multiple serial commands.

Table 6-1lists the RS-232 command set. The “Parameter (min/max)” column shows the valid parameter ranges, or “NA” for commands that take no parameters.

When you enter a valid command, the DHD Controller executes it and acknowledges it with a plus sign on the command line (+ >). When you enter an invalid command – one that is misspelled or followed by values outside the valid range for that command – the DHD Controller ignores it and returns a minus sign (- >).

Table 6-1. Serial Commands

Command

Parameter

 

Value

Description

(min/max)

 

Stored?

 

 

 

 

 

 

 

 

 

 

Power On/Off Commands

 

 

 

 

 

OFF

NA

 

NA

Turns system off

 

 

 

 

 

ON

NA

 

NA

Turns system on

 

 

 

 

 

POWER

0/1

 

NA

Turns system on or off (toggles on/off state)

 

 

 

 

 

POWER?

NA

 

NA

Returns power status

 

 

 

 

 

6.1

RS-232 Connection and Port Configuration

6.2

Serial Command Syntax

Runco PL-43DHD and PL-50DHD Owner’s Operating Manual

49

Page 59
Image 59
Runco PL-43DHD, PL-50DHD manual Serial Communications, Value Description Min/max Stored? Power On/Off Commands