Russound CAM6.6T ZONE SETUP ZonSu, CTRLR SETUP CtlId, See Zone Setup - Flow Chart on page

Models: CAM6.6 CAM6.6T

1 116
Download 116 pages 17.9 Kb
Page 58
Image 58
ZONE SETUP (ZonSu)

INSTALLER

INSTALLATION MENU

ZONE SETUP (ZonSu)

NOTE: This procedure should be performed using the keypad installed in the zone to be configured.

See Zone Setup - Flow Chart on page 71

Zone Setup allows the installer to adjust properties of the UNO Keypad controlled CAM6.6 zone. This series of menus allows the system’s zones to be configured for these properties:

ZON VOL TRIM (ZonVT)

 

 

 

SYSON ENABLE (SysOn)

 

 

PARTY ENABLE (PtyEn)

 

 

 

 

 

 

MASTER ENABL (MstEn)

 

MUTE ENABLE (MutEn)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

ZON VOL TRIM

 

This feature allows the installer to adjust the output volume to

 

(ZonVT)

 

each zone. -16dB (lowest) to 0dB (max)(-3DB default).

2.

SYSON ENABLE

 

This feature is either disabled or enabled. If disabled (default), an

 

(SysOn)

 

All On command activated from another zone will not turn on the

 

 

 

 

 

disabled zone. If enabled, an All On command activated from

 

 

 

 

 

another zone will turn on the enabled zone.

3.

PARTY ENABLE

 

This feature is either disabled or enabled. If disabled, Party Mode

 

(PtyEn)

 

activation from another zone will not affect the disabled zone. If

 

 

 

 

 

enabled (default), the zone will participate with Party Mode.

4.

MASTER ENABLE

 

This feature is either disabled or enabled. If disabled, the zone

 

(MstEn)

 

cannot host a master keypad during Party Mode. If enabled

 

 

 

 

 

(default), the zone has the option of hosting the Master keypad.

5.

MUTE ENABLE

 

This feature is either disabled or enabled. It allows the option of

 

(MutEn)

 

enabling or disabling muting in a zone. If disabled, the zone will

 

 

 

 

 

not mute. If enabled (default), the zone will be muted when a

 

 

 

 

 

mute signal is received.

 

 

 

 

 

CTRLR SETUP (CtlId)

Controller Setup is the basic configuration of the controller. This setup menu selects the options for Controller ID and Factory Initialization. See Controller Setup - Flow Chart on page 72

1. CONTROLLER ID

This defines the Controller ID for this system. The default is 1 but

(CtlId)

when multiple controllers are used, each additional controller ID

 

must be sequential and unique and be set before being connect-

 

ed to the system. Note that the system must be restarted before

 

the controller will assume the new ID.

 

(continued next page)

58

Page 58
Image 58
Russound CAM6.6T ZONE SETUP ZonSu, CTRLR SETUP CtlId, See Zone Setup - Flow Chart on page, ZON VOL TRIM ZonVT, Mute Enable