RJ-45 Connections
The
Keypad Wiring
For the KP4 or KPL keypad, the following con- nections are used to terminate the
| TYPE |
Brown. . . . . . . . . . . . . . . . . . . . . +12V
Brown/White. . . . . . . . . . . . . . . . +12V
Green . . . . . . . . . . . . . . . . . . . Ground
Green/White . . . . . . . . . . . . . Status In
Orange . . . . . . . . . . . . . . . . . . Ground
Orange/White . . . . . . . . . . . . . . IR Out
Blue. . . . . . . . . . . . . . . . . . . . . COM A
Blue/White. . . . . . . . . . . . . . . . COM B
•To determine the amount of
•Make sure that the entire wire path between keypads and CAS44 is clear and not obstructed by a floor ceiling joist, or masonry wall which can’t be drilled through.
INSTALLER
WIRING OVERVIEW
•Confirm ahead of time that you can drill an outlet hole easily and in an unobtrusive spot to connect wires with the CAS44.
•Label wires with keypad and room location. This simplifies CAS44
Speaker Wiring
Standard
When running wire, pay particular attention to the following areas:
•Avoid locations concealing pipes, heating ducts and AC wiring in the general vicinity.
•Avoid running wires close to house electrical wiring for any distance. If you have to run them parallel, make sure to space the wires at least two feet from the AC line.
13