INSTALLER GUIDE
UNO-TS2 Touchscreen Connections
CAT-5 Connection
The
Punchdown terminals require the use of a punchdown tool. Attach the
Caution
Take care when using an impact 110 punchdown tool, as this may overspread the contact points. Use of the impact tool may propel stray bits of wire and jacket into the keypad’s chassis and possibly cause a short in the circuitry. Gently shake or blow air through the keypad chassis to remove stray wire before the keypad is installed into the junction box.
The
Keypad Wiring
For the UNO touchscreen, the following connections are used to terminate the
| TYPE |
Brown | +12V |
Brown/White | +12V |
Green | Ground |
Green/White | Status In |
Orange | Ground |
Orange/White | IR Out |
Blue | COM A |
Blue/White | COM B |
Installation Considerations
The best infrared remote performance is achieved with the touchscreen away from any direct sunlight, plasma TV, and low voltage lighting controls. Also consider con- venience when choosing a location.
•The maximum recommended wire run length is 250 feet for each UNO touchscreen.
•Make sure that the entire wire path between key- pads and the controller is clear and not obstructed by a floor ceiling joist, or masonry wall which can’t be drilled through.
•Confirm ahead of time that you can drill an outlet hole easily and in an unobtrusive spot to connect wires with the controller.
•Label wires with keypad and room location. This simplifies connections once the keypads and speak- ers are installed.
OS Update Port
The OS Update Port is is used to update the
18