INSTALLER GUIDE

UNO-TS2 Overview

UNO-TS2 Overview for Installers

Note: The following minimum firmware revisions are required for use with the UNO-TS2:

CAV6.6 Rev. 3

2.01.16 or higher

CAV6.6 Rev. 4

3.01.10 or higher

CAM6.6

1.01.05 or higher

CAM Internal AM/FM Tuner

1.01.01 or higher

CAM Internal XM Module

2.00.05 or higher

ST2 Dual Tuner

3.00.10 or higher

ST2-XM (ST2 Chassis)

3.00.10 or higher

ST2-XM (XM Module)

2.00.05 or higher

SMS3 Media Server

2.00.07 or higher

The UNO-TS2 is an RNET-system enabled touch- screen that functions similarly to the UNO-S2 keypad. It fits into a double-gang 32ci low volt- age PVC junction box, uses a CAT-5 110 punch- down connection, and supports one external IR receiver. Active system status icons appear on the screen (shared, master, party and do not dis- turb). An “All On” or “All Off” can be performed by pressing and holding the power button.

The CAV6.6 or CAM6.6 controller can NOT be configured from the UNO-TS2. Controller configu- ration must be performed using an UNO-S2 key- pad or the PC Power Tool program.

For One UNO-TS2 per Controller

Note: 12V Zone triggers cannot be used with this keypad configuration.

An RNET controller (CAV6.6, CAM6.6) supports one UNO-TS2 and up to five UNO keypads per controller, connected to the UNO System Keypad Ports located on the back of the controller.

For 2 to 6 UNO-TS2s per Controller

(One UNO-TS2 per Zone)

Each UNO-TS2 must be connected to an SA-ZX3 Keypad Splitter. The SA-ZX3 is powered by a 1201A 1A power supply and uses an RJ-45 CAT-5 patch cable to connect to the controller’s UNO Keypad Port. UNO-S1/S2 keypads can

share the SA-ZX3 with an UNO-TS2, but they must be configured for the same zone.

After sources are configured in the RNET sys- tem, they must be configured in the UNO-TS2 using a simple onscreen process under Installers Setup. The configured source names (up to 6) appear on the UNO-TS2 main screen, and unas- signed source buttons remain blank. Custom source names are set up in the optional PC Power Tools program, and standard names are set up with an UNO-S1 or UNO-S2 keypad.

The UNO-TS2 features pre-configured source templates. Due to the unique screens used for each source, the UNO-TS2 does not support the key mapping features of the UNO-S1/S2 key- pads. Custom key configuration (Key Configuration menu of controller) is not recom- mended and may result in unexpected behavior by the UNO-TS2.

The UNO-TS2 screen blanker darkens the screen when it has not been touched for a certain amount of time. A touch to the screen brings the screen back. This screen blank time can be adjusted from 0 minutes (disables screen blanker) to over an hour.

The UNO-TS2 may require future updates for screens and for firmware. These updates are performed in a similar fashion as UNO-S2 updates, with a programming cable and a PC.

15

Page 15
Image 15
Russound manual Installer Guide, UNO-TS2 Overview for Installers, For One UNO-TS2 per Controller