PATTERN can be set upto 3. Choose 1, 2, or 3 with the left or right key in the "PATTERN SET" and press [ENTER] to get into the PATTERN set up screen. From the moment "PATTERN 1 SET" is gone for 30 seconds, it memorizes the MANUAL movements and after 30 seconds it will return to a higher menu. If you
want to finish set up before the
5. ALARM SET
It consists of 4 ALARM INPUTs and 3 ALARM OUTs.It can sense an ALARM input from exterior SENSORs and it performs with PRESET or PATTERN function and outputs the ALARM OUT signals.
It recognizes the ALARM signal input as an ALARM signal when it continues more than 150ms for a time and each ALARM movement time
is decided depending on it's correspondence to the DWELL TIME of the PRESET and PATTERN connected.
ALARM OUT
Each ALARM input corresponds to one of the 3 ALARM OUT.
ALARM PATTERN
This sets the operation of PATTERN movements when inputting ALARM.
When the ALARM is working, it will stay in the PRESET location corresponding the ALARM for the DWELL TIME and the ALARM connected to the PATTERN will continuously operate the PATTERN movements.
ALARM OUT
ALARM1 1
ALARM2 2
ALARM3 3
ALARM4 2
MOTION 1
EXITQUIT
E
ALARM PATTERN
ALARM1 OFF
ALARM2 OFF
ALARM3 1
ALARM4 2
MOTION 3
* * MAIN MENU * *
CAMERA... | ➜ | ||
| |||
VIDEO SET... | Press | ||
PRESET... | |||
[Enter] | |||
AUTO MODE... | |||
| |||
|
| ||
ALARM SET... |
|
| |
OTHER SET... |
|
( ALARM SET)
ALARM PRIORITY SET.. ALARM IN SET..
ALARM OUT SET.. ALARM PATTERN SET.. AUX OUT CONTROL..
RET
When the ALARM is inputted the correspondence
will be as follows: ALARM1 input to PRESET 1, ALARM 2 input to PRESET 2, ALARM3 input to PRESET 3, ALARM 4 input to PRESET 4, and MOTION input to PRESET 5.
EXITQUIT
ALARM PRIORITY SET
This sets the priority of the 4 ALARM inputs so ALARM can work corresponding to the priority. The priority of the DEFAULT is ALARM1: 1, ALARM2: 2, ALARM3: 3, ALARM4: 4, MOTION: 5. If the ALARM is working at the same time and the priority is the same, it will operate according to the DEFAULT priority. While the ALARM is working, it cannot detect MOTION.
ALARM IN SET
This sets the input TYPE to "NO" (Normal Open), "NC" (Normal Close), or "OFF" depending on the features of the SENSOR connected.
ALARM PRIORITY |
|
ALARM1 | 1 |
ALARM2 | 2 |
ALARM3 | 3 |
ALARM4 | 4 |
EXIT | QUIT |
ALARM IN
ALARM1 NO
ALARM2 NC
ALARM3 NO
ALARM4 NC
EXITQUIT
The OFF in the Setup Menu does not operate the PATTERN, and it means 1 ➞ PATTERN1, 2 ➞ PATTERN 2, 3 ➞ continuous motion of PATTERN 1 + PATTERN 2, HALF 2 motion of PATTERN 2 + PATTERN 3 and FULL PATTERN 1+PATTERN2+PATTERN3.
AUX OUT CONTROL
This sets the ALARM OUT motion to continue or act only when the ALARM is working.
If it is set to OFF the ALARM OUT motion will operate only when the ALARM is working.
(Active "Low"), and if it's set to ON, the ALARM OUT will always operate regardless of the ALARM.
PATTERN 3, HALF1 | ➞ |
➞continuous
➞continuous motion of
AUX OUT
OUT1 OFF
OUT2 OFF
OUT3 ON
EXITQUIT