PATTERN can be set upto 3. Choose 1, 2, or 3 with the left or right key in the "PATTERN SET" and press [ENTER] to get into the PATTERN set up screen. From the moment "PATTERN 1 SET" is gone for 30 seconds, it memorizes the MANUAL movements and after 30 seconds it will return to a higher menu. If you

want to finish set up before the 30-second ends, press [ENTER].

5. ALARM SET

It consists of 4 ALARM INPUTs and 3 ALARM OUTs.It can sense an ALARM input from exterior SENSORs and it performs with PRESET or PATTERN function and outputs the ALARM OUT signals.

It recognizes the ALARM signal input as an ALARM signal when it continues more than 150ms for a time and each ALARM movement time

is decided depending on it's correspondence to the DWELL TIME of the PRESET and PATTERN connected.

ALARM OUT

Each ALARM input corresponds to one of the 3 ALARM OUT.

ALARM PATTERN

This sets the operation of PATTERN movements when inputting ALARM.

When the ALARM is working, it will stay in the PRESET location corresponding the ALARM for the DWELL TIME and the ALARM connected to the PATTERN will continuously operate the PATTERN movements.

ALARM OUT

ALARM1 1

ALARM2 2

ALARM3 3

ALARM4 2

MOTION 1

EXITQUIT

E

ALARM PATTERN

ALARM1 OFF

ALARM2 OFF

ALARM3 1

ALARM4 2

MOTION 3

* * MAIN MENU * *

CAMERA...

 

VIDEO SET...

Press

PRESET...

[Enter]

AUTO MODE...

 

 

 

ALARM SET...

 

 

OTHER SET...

 

( ALARM SET)

ALARM PRIORITY SET.. ALARM IN SET..

ALARM OUT SET.. ALARM PATTERN SET.. AUX OUT CONTROL..

RET

When the ALARM is inputted the correspondence

will be as follows: ALARM1 input to PRESET 1, ALARM 2 input to PRESET 2, ALARM3 input to PRESET 3, ALARM 4 input to PRESET 4, and MOTION input to PRESET 5.

EXITQUIT

ALARM PRIORITY SET

This sets the priority of the 4 ALARM inputs so ALARM can work corresponding to the priority. The priority of the DEFAULT is ALARM1: 1, ALARM2: 2, ALARM3: 3, ALARM4: 4, MOTION: 5. If the ALARM is working at the same time and the priority is the same, it will operate according to the DEFAULT priority. While the ALARM is working, it cannot detect MOTION.

ALARM IN SET

This sets the input TYPE to "NO" (Normal Open), "NC" (Normal Close), or "OFF" depending on the features of the SENSOR connected.

ALARM PRIORITY

 

ALARM1

1

ALARM2

2

ALARM3

3

ALARM4

4

EXIT

QUIT

ALARM IN

ALARM1 NO

ALARM2 NC

ALARM3 NO

ALARM4 NC

EXITQUIT

The OFF in the Setup Menu does not operate the PATTERN, and it means 1 PATTERN1, 2 PATTERN 2, 3 continuous motion of PATTERN 1 + PATTERN 2, HALF 2 motion of PATTERN 2 + PATTERN 3 and FULL PATTERN 1+PATTERN2+PATTERN3.

AUX OUT CONTROL

This sets the ALARM OUT motion to continue or act only when the ALARM is working.

If it is set to OFF the ALARM OUT motion will operate only when the ALARM is working.

(Active "Low"), and if it's set to ON, the ALARM OUT will always operate regardless of the ALARM.

PATTERN 3, HALF1

continuous

continuous motion of

AUX OUT

OUT1 OFF

OUT2 OFF

OUT3 ON

EXITQUIT

3-20

3-21