PRIVACY ZONE SET 1

SET PAN/TILT ...

SET AREA

...

 

 

 

 

 

 

 

 

SET LEVEL

1

EXIT

 

QUIT

[Down] KEY

PRIVACY ZONE SET 1

SET PAN/TILT ...

SET AREA

 

...

 

 

 

 

 

 

 

 

SET LEVEL

1

EXIT

 

QUIT

[Enter] KEY

Entering the

AREA Setup

Mode

Product specifications

ED2250S/P

NO

Items

Contents

1

Product Type

- Zoom lens single body COMBI DOME CAMERA

2

Power Input

- AC 24 ± 10% (50Hz ± 0.3Hz)

3

Power Consumption

- 18W

4

Broadcasting Type

- PAL STANDARD COLOR SYSTEM

To set the area, select "SET AREA" and then press the [Enter] key. With OSD showing "SET", use the [up, down, left, right] key to set the AREA size.

5

Image Device

- 1/4 inch IT CCD

 

6

Effective Pixels

- 752(H)x 582(V)

7

Scanning Mode

- 625 Lines, 2:1 Interlace

8

Scanning line Frequency

- Horizontal : 15,

625 Hz(INT) / 15, 625 Hz(L/L)

Vertical : 50

Hz(INT) / 50 Hz(L/L)

 

 

9

Synchronization Mode

- INT/LINE LOCK

E

PRIVACY ZONE SET 1

SET PAN/TILT ...

SET AREA

 

SET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SET LEVEL

1

EXIT

QUIT

[Enter] KEY

The AREA

Setup is

complete.

PRIVACY ZONE SET 1

SET PAN/TILT ...

SET AREA

...

 

 

 

 

 

 

 

 

SET LEVEL

1

EXIT

 

QUIT

10

Resolution

- 480 TV LINES

11

S/N Ratio

- 52dB (AGC OFF)

 

 

- 0.3 Lux (SENS UP X4)

12

Min. Object Illumination

(0.01Lux)

 

 

- B/W : 0.4 Lux

 

 

(0.003 Lux)

13

Color Temperature

- ATW/AWC/MANUAL MODE

(3200 °K , 5600 °K , R/B GAIN Court)

 

 

 

14

Signal Output

- COMPOSITE VIDEO OUT : 1.0 Vp-p 75 ohms/BNC

Select "SET LEVEL" and set the Level of Mask Area.

This Level can be set anywhere from 1 (black) to 8 (white), and the set level will be applied to all eight areas.

"SAVE" and exit after setting the Level to complete the settings for the Privacy Zone.

Make the area large enough so that the relevant area can be hidden undermeath it.

CAM RESET

CAM RESET clears all the settings made so far and restores the factory default settings.

"CAMERA RESET?" message appears when you select CAM RESET. Select "CANCEL" to return to the menu setup display or select OK to restore the factory default settings.

Be careful when performing a CAM RESET operation, as it deletes all setup values.

3-24

-one body; 22X Zoom lens

-Focal length : 3.6 to 79.2 mm

15Lens

-Aperture : F1.6(Wide), F3.8(Tele)

-Auto Focus

 

 

- PAN range : 360

° Endless

16

PAN Function

- Preset Pan Speed : 240

° /sec, maximum

 

 

- Manual Pan Speed : 0.8

° ~ 90 ° /sec (64Step)

 

 

- TILT range : 0

° ~ 90 °

 

17

TILT Function

- Preset Tilt Speed

: 150

° /sec, maximum

 

 

- Manual Tilt Speed : 0.8

° ~ 45 ° /sec (64Step)

18

REMOTE CONTROL

- Tele/Wide(ZOOM), Near/Far(FOCUS),

Iris Open/Close, Pan/Tilt

 

 

 

 

 

 

- Alarm Inputs : 4 IN(5mA Sink)

 

19

ALARM

- Alarm Outputs : 3 OUT (Open collector : 2

DC24V 40mA Max, Relay : 1, NO, NC, COM

 

 

 

 

2A 30VDC, 0.5A 125VAC Max)

 

20

Operation Temperature

- 14 °F ~ 122 °F

 

 

21

Operation Humidity

- ~90%

 

 

22

SIZE

- DOME : 147 (

ø),

 

Outline : 159.5(

ø) x 176(H)(Adapter:23.5(H)mm)

 

 

23

Weight

- 2Kg

 

 

3-25

Page 27
Image 27
Samsung ED2250S/P manual Product specifications, CAM Reset, Select SET Level and set the Level of Mask Area