8.2.34 SMART (B0h)

Individual SMART commands are identified by the value placed in the Feature resister. Below depicts these Feature register values.

Table 8-14 SMART Feature Registers Values

Feature Value

Command

D0h

SMART READ DATA

D1h

Obsolete (SMART Read Threshold)

D2h

SMART ENABLE/DISABLE ATTRIBUTE AUTOSAVE

D3h

Obsolete (SMART Save Attribute Value)

D4h

SMART EXECUTE OFF-LINE IMMEDIATE

D5h

SMART READ LOG SECTOR

D6h

SMART WRITE LOG SECTOR

D7h

Obsolete

D8h

SMART ENABLE OPERATIONS

D9h

SMART DISABLE OPERATIONS

DAh

SMART RETURN STATUS

DBh

Obsolete (Enable/Disable Auto Offline Scan)

DCh-DDh

Reserved

DEh

Reserved (Initialize SMART Variables)

DFh

Reserved

8.2.34.1Smart disable operations (D9h)

This command disables all SMART capabilities within the device including any timer and event count functions related to this feature. After receipt of this command the device shall disable all SMART operations. SMART data shall no longer be monitored or saved by the device. The state of SMART (either enabled or disabled) shall be preserved by the device across power cycles.

After receipt of this command by the device, all other SMART commands (including SMART DISABLE OPERATIONS commands), with the exception of SMART ENABLE OPERATIONS, are disabled and invalid and shall be command aborted by the device.

8.2.34.2Smart enable/disable attribute auto-save (D2h)

This command enables and disables the optional attribute auto-save feature of the device. Depending upon the implementation, this command may either allow the device, after some vendor specified event, to automatically save its updated attribute values to non-volatile memory; or this command may cause the auto- save feature to be disabled. The state of the attribute auto-save feature (either enabled or disabled), shall be preserved by the device across power cycles.

A value of zero written by the host into the device’s Sector Count register before issuing this command shall cause this feature to be disabled. Disabling this feature does not preclude the device from saving SMART data to non-volatile memory during some other normal operation such as during a power-on sequence or during an error recovery sequence.