Setting the ALARM / RELAY Out

(1)Connect the alarm sensor to another device according to the ‘Chapter 3 Connecting to Instruments’. The alarm level of the alarm terminal 1~4 is the following.

Normal condition : TTL High Level (DC 5V)

Alarm : TTL Low Level (DC 0V)

(2)If the alarm is set off the SNS-110 sends video images connected to alarm terminal 1~4, by E-mail or to the FTP server on a set time gap. 5 frames for E-mail and 999 frames for FTP can be transferred, and the E-mail with preset messages and video images can also be transferred.

(3)In the Administration Mode this settings window will be seen with a click on the "Alarm/Relay" icon.

(4)Status

The present status on the Relay Out terminal of the reverse side of the SNS-110. The toggle shaped "Turn On/Off" button is used to control the external device connected to the Relay Out terminal.

(5)Sender

In order to send alarm messages and video images by E-mail, the E-mail address must be entered so as to identify the sender. If the E-mail address is invalid the alarm messages and the video images may not be sent as wanted.

Recommend

Please, set the valid e-mail address of SNS-110 administrator at e-mail the ‘sender’.