Samsung SPD-3000 Controller Connection Terminal Camera Holder, Setting Termination Resistance

Models: SPD-2300

1 66
Download 66 pages 25.64 Kb
Page 11
Image 11
Controller Connection Terminal (Camera Holder)

Part Names and Functions

Controller Connection Terminal (Camera Holder)

 

NAME

Purpose

CON7- #1

RXD+

Controller Data Line Connection

CON7-#2

RXD-

Controller Data Line Connection

CON7-#3

TXD+

Controller Data Line Connection

CON7-#4

TXD-

Controller Data Line Connection

CON7-#5

GND

GND

CON7-#6

TX

For RS-232 Communication

CON7-#7

RX

For RS-232 Communication

Alarm Connection Terminal (Camera Holder)

 

NAME

Purpose

IJP3 - #1

IN1

Alarm input sensor connection terminal 1

IJP3 - #2

IN2

Alarm input sensor connection terminal 2

IJP3 - #3

GND

GND

IJP3 - #4

IN3

Alarm input sensor connection terminal 1

IJP3 - #5

IN4

Alarm input sensor connection terminal 1

IJP3 - #6

GND

GND

IJP3 - #7

COM1

Alarm Output 1 Common

IJP3 - #8

1N.O

Alarm Output 1 (for Normal Open)

IJP3 - #9

1N.C

Alarm Output 1 (for Normal Close)

IJP3 - #10

COM2

Alarm Output 2

Auxiliary Output 1 common

IJP3 - #11

2N.O

Alarm Output 2 (NO)

Auxiliary Output 1 (NO)

IJP3 - #12

2N.C

Alarm Output 2 (NC)

Auxiliary Output 1 (NC)

Notes

• Auxiliary output correpondence of Alarm output is vaild in AD Protocol

Setting Termination Resistance

In order to prevent signal reduction, the termination resistance of the 2 end units, which are the distant paths for camera and controller to be connected on the RS485 interface, should be connected.

As the termination resistance is built in the camera, whether to make the termination resistance valid or invalid is selected with the DIP switch.

See the connection diagram below for determining to which device the termination resistance will be connected to.

Set up the termination resistance in the dark products.

The installation distance of the product for the termination resistance setting should be less than 1.2 Km. (Maximum cable length is 1.2 Km according to the RS-485 standards.)

ENGLISH

SPEED DOME CAMERA 20 User’s Manual

SPEED DOME CAMERA 21 User’s Manual

Page 11
Image 11
Samsung SPD-3000, SPD-2300 Controller Connection Terminal Camera Holder, Alarm Connection Terminal Camera Holder, English