Samsung SPD-2300, SPD-3000 user manual Alarm Setting, Functional Description, English

Models: SPD-2300

1 66
Download 66 pages 25.64 Kb
Page 28
Image 28
5) Alarm Setting

Functional Description

PTZ Position : Pan and Tilt position and Zoom magnification are displayed.

PTZ positions are not displayed in the OFF mode. (Only manual operation can display them.)

Main Menu

OSD Setting

 

Camera Setting

Camera ID

ON

Sequence Setting

Camera Name

 

P/T Setting

Preset Number

ON

OSD Setting

Preset Name

 

Sequence Status

OFF

Alarm Setting

Area Name

OFF

Initialize

PTZ Position

ON

Status

Language

English

 

Language : The OSD can be displayed either in English (default setting) or in Chinese.

Main Menu

OSD Setting

 

Camera Setting

Camera ID

ON

Sequence Setting

Camera Name

 

P/T Setting

Preset Number

ON

OSD Setting

Preset Name

 

Sequence Status

OFF

Alarm Setting

Area Name

OFF

Initialize

PTZ Position

ON

Status

Language

English

 

5) Alarm Setting

Manual backgroundAlarm Enable : It can be determined whether to enable the alarm setting.

Main Menu

Alarm Setting

 

Camera Setting

Alarm Enable

ON

Sequence Setting

Alarm Input

 

P/T Setting

Alarm Output

 

OSD Setting

MD Dwell Time

ON 30 SEC

Alarm Setting

 

 

Initialize

 

 

Status

 

 

Manual backgroundON/OFF : Alarm is enabled in ON mode.

Manual backgroundAlarm Input : Alarm Input Mode/Priority/Method is set up.

Alarm Setting

 

 

Alarm Input

 

 

Alarm Enable

ON

 

IN

1

OFF

1

OFF

Alarm Input

 

 

IN

2

OFF

2

OFF

Alarm Output

 

 

IN

3

OFF

3

OFF

MD Dwell Time

ON

30 SEC

IN

4

OFF

4

OFF

Manual backgroundNC/NO/OFF : NC/NO/OFF can be selected depending on the alarm sensor.

Manual background1 - 4 (Priority) : Priority for the 4 alarm inputs is set up. Response comes first from the alarm input of higher priority.

Manual backgroundPreset/Swing/Group/Tour/Trace/A.Pan:

Whether to enable the operation of Preset/Swing/Group/Tour/Trace/A.Pan by alarm input can be set up. When the alarm is input, it stays in the preset/Swing/ Group/Tour/Trace/A.Pan position.

Manual backgroundAlarm Out : One of the 2 Alarm Outs corresponds to each Alarm input.

Alarm Setting

 

Alarm Output

 

 

 

 

 

Alarm Enable

ON

Setting

1

1

2

3

4

MD

Alarm Input

 

Setting

2

1

2

3

4

MD

Alarm Output

 

Timer

1

OFF

 

 

 

 

MD Dwell Time

ON 30 SEC

Timer

2

OFF

 

 

 

 

 

 

OUT Off

1

 

 

 

 

 

 

 

OUT Off

2

 

 

 

 

 

OUT1 SET/OUT2 SET

: One of the 4 Alarm Inputs corresponds to the 2 Alarm Outputs.

OUT1 TIME/OUT2 TIME

: For the 2 Alarm Outputs, On/Off and the operation time can be

 

set up in the units of second/minute/hour. (1-59 sec, 1-59 min,

 

1-59 hour)