SVR-1650/1640/950 User Manual

3. External control equipment (RS-422/485)

This is a terminal for connecting external control equipment.

The switch labeled TERM is used to turn ON/OFF terminating resistance for RS–422/485 communication equipment.

3

PORT

No.

RS-422

RS-485

 

1

RX+ (+Data Receive)

Data+

 

2

RX- (-Data Receive)

Data-

PORT A

3

N/C (Not connected)

N/C (Not connected)

4

N/C (Not connected)

N/C (Not connected)

(Controller

5

GND(Ground)

GND(Ground)

SCC-3100A Control)

6

N/C (Not connected)

N/C (Not connected)

 

 

7

Tx-(-Data Send)

Data-

 

8

Tx+(+Data Send)

Data+

 

9

Rx+(+Data Receive)

Data+

 

10

Rx-(-Data Receive)

Data-

PORT B

11

N/C (Not connected)

N/C (Not connected)

12

N/C (Not connected)

N/C (Not connected)

(Speed Dome Control)

13

GND(Ground)

GND(Ground)

 

14

N/C (Not connected)

N/C (Not connected)

 

15

Tx-(-Data Send)

Data-

 

16

Tx+(+Data Send)

Data+

TERM 1 switch controls PORT A, TERM 2 Switch controls PORT B 1, 2 : ON RS-485 MODE, OFF .RS-422 MODE

3, 4 : ON Termination On, OFF Termination Off

27

Page 29
Image 29
Samsung SVR-1640, SVR-950 user manual External control equipment RS-422/485, RS-422 RS-485, Port a, Port B