5-2. Cooling Capacity
Indoor Unit | : | KS3082 |
|
|
|
|
|
|
|
|
|
|
| ||
Outdoor Unit | : | C3082 |
|
|
|
|
|
|
|
|
|
|
|
| |
Power Supply : 230V Single Phase 60Hz |
|
|
|
|
|
|
|
| |||||||
| < Cooling Capacity (Low Ambient) > |
|
|
|
|
|
|
| |||||||
| RATING CAPACITY: | 30,600 BTU/h |
| AIR FLOW RATE: |
| 630 CFM | |||||||||
|
|
| INDOOR |
|
|
|
|
| OUTDOOR |
|
|
| |||
|
| ENT. TEMP. oF (oC) |
|
|
|
| AMBIENT TEMP. oF (oC) |
|
| ||||||
|
|
| W.B. | D.B. |
|
| 0 | 5 | 15 | 25 |
| 35 | 45 | 55 | |
|
|
|
|
|
|
|
|
| (1.7) | (7.2) | (12.8) | ||||
|
|
|
|
|
| TC |
| 30,120 | 30,060 | 29,930 | 29,780 |
| 29,590 | 29,330 | 29,070 |
|
|
|
| 72 | (22.2) | SHC |
| 21,150 | 21,150 | 21,020 | 20,900 |
| 20,780 | 20,660 | 20,530 |
|
|
| 59 | 76 | (24.4) | SHC |
| 23,470 | 23,470 | 23,350 | 23,230 |
| 23,230 | 22,980 | 22,860 |
|
| (15.0) | 80 | (26.7) | SHC |
| 25,920 | 25,920 | 25,790 | 25,790 |
| 25,670 | 25,430 | 25,300 | |
|
|
|
| 84 | (28.9) | SHC |
| 28,240 | 28,240 | 28,120 | 28,120 |
| 27,990 | 27,870 | 27,630 |
|
|
|
| 88 | (31.1) | SHC |
| 30,120 | 30,060 | 29,930 | 29,780 |
| 29,590 | 29,330 | 29,070 |
|
|
|
|
|
| TC |
| 30,390 | 30,360 | 30,270 | 30,170 |
| 30,040 | 29,820 | 29,610 |
|
|
|
| 72 | (22.2) | SHC |
| 17,720 | 17,720 | 17,600 | 17,600 |
| 17,480 | 17,360 | 17,360 |
|
|
| 63 | 76 | (24.4) | SHC |
| 20,050 | 20,050 | 19,920 | 19,920 |
| 19,800 | 19,800 | 19,680 |
|
| (17.2) | 80 | (26.7) | SHC |
| 22,490 | 22,490 | 22,370 | 22,370 |
| 22,370 | 22,250 | 22,120 | |
|
|
|
| 84 | (28.9) | SHC |
| 24,820 | 24,820 | 24,820 | 24,690 |
| 24,690 | 24,570 | 24,450 |
|
|
|
| 88 | (31.1) | SHC |
| 27,140 | 27,140 | 27,140 | 27,020 |
| 27,020 | 26,890 | 26,770 |
|
|
|
|
|
| TC |
| 30,490 | 30,480 | 30,450 | 30,400 |
| 30,330 | 30,160 | 30,020 |
|
|
|
| 72 | (22.2) | SHC |
| 14,180 | 14,180 | 14,180 | 14,180 |
| 14,180 | 14,050 | 14,050 |
|
|
| 67 | 76 | (24.4) | SHC |
| 16,500 | 16,500 | 16,500 | 16,500 |
| 16,500 | 16,380 | 16,380 |
|
| (19.4) | 80 | (26.7) | SHC |
| 19,070 | 18,940 | 18,940 | 18,940 |
| 18,940 | 18,820 | 18,820 | |
|
|
|
| 84 | (28.9) | SHC |
| 21,390 | 21,390 | 21,390 | 21,270 |
| 21,270 | 21,150 | 21,150 |
|
|
|
| 88 | (31.1) | SHC |
| 23,710 | 23,710 | 23,710 | 23,710 |
| 23,590 | 23,590 | 23,470 |
|
|
|
|
|
| TC |
| 30,370 | 30,380 | 30,410 | 30,430 |
| 30,420 | 30,310 | 30,250 |
|
|
|
| 72 | (22.2) | SHC |
| 10,510 | 10,510 | 10,510 | 10,630 |
| 10,630 | 10,510 | 10,510 |
|
|
| 71 | 76 | (24.4) | SHC |
| 12,950 | 12,950 | 12,950 | 12,950 |
| 12,950 | 12,830 | 12,830 |
|
| (21.7) | 80 | (26.7) | SHC |
| 15,400 | 15,400 | 15,400 | 15,400 |
| 15,400 | 15,280 | 15,280 | |
|
|
|
| 84 | (28.9) | SHC |
| 17,720 | 17,720 | 17,720 | 17,720 |
| 17,720 | 17,720 | 17,600 |
|
|
|
| 88 | (31.1) | SHC |
| 20,050 | 20,050 | 20,050 | 20,050 |
| 20,050 | 20,050 | 20,050 |
|
|
|
|
|
| TC |
| 30,030 | 30,080 | 30,170 | 30,240 |
| 30,310 | 30,250 | 30,270 |
|
|
| 75 | 76 | (24.4) | SHC |
| 9,410 | 9,410 | 9,410 | 9,530 |
| 9,530 | 9,530 | 9,530 |
|
| (23.9) | 80 | (26.7) | SHC |
| 11,850 | 11,850 | 11,850 | 11,970 |
| 11,970 | 11,970 | 11,970 | |
|
|
|
| 84 | (28.9) | SHC |
| 14,180 | 14,180 | 14,300 | 14,300 |
| 14,300 | 14,300 | 14,300 |
|
|
|
| 88 | (31.1) | SHC |
| 16,500 | 16,620 | 16,620 | 16,620 |
| 16,620 | 16,620 | 16,620 |
|
|
|
|
|
| TC : Total Cooling Capacity (BTU/h) | SHC : Sensible Heat Capacity (BTU/h) |
NOTE
1.Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics.
2.Above data represents the value when the operation frequency of a compressor is fixed.
21