Indoor Unit

KS3682

 

 

 

 

Outdoor Unit

C3682

 

 

 

 

(1) Voltage:230V

 

 

 

 

 

 

Cooling

 

 

 

 

 

 

< 230V >

 

 

 

 

 

Indoor Unit

Outdoor Unit

Complete Unit

 

 

 

 

 

Fan Motor

Fan Motor + Compressor

 

 

 

 

 

 

Performance at

 

 

 

 

230V Single-phase 60Hz

 

Rating conditions

 

Running amp.

A

0.4

19.6

20.0

 

 

 

Power input

W

39

3,961

4,000

Rating conditions:

Indoor air temperature:

80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.

 

 

 

Outdoor air temperature:

95°F (35°C) D.B.

 

 

(2) Voltage:208V

 

 

 

 

 

 

Cooling

 

 

 

 

 

 

< 208V >

 

 

 

 

 

Indoor Unit

Outdoor Unit

Complete Unit

 

 

 

 

 

Fan Motor

Fan Motor + Compressor

 

 

 

 

 

 

Performance at

 

 

 

 

208V Single-phase 60Hz

 

Rating conditions

 

Running amp.

A

0.4

21.5

21.9

 

 

 

Power input

W

39

3,961

4,000

Rating conditions:

Indoor air temperature:

80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.

 

 

 

Outdoor air temperature:

95°F (35°C) D.B.

 

 

28

Page 28
Image 28
Sanyo C3082 service manual C3682 Voltage230V Cooling