2-2. Outdoor Unit

AVOID:

heat sources, exhaust fans, etc. (Fig. 4)

damp, humid or uneven locations.

DO:

choose a place as cool as possible.

choose a place that is well ventilated.

install in a location where at least two sides are unob- structed, so that the flow of air at the intake port or exhaust port is not blocked, and so that sufficient space is ensured for maintenance to be carried out without trouble. In general the top also must be unob- structed. (Fig. 5a)

provide a solid base (level concrete pad, concrete block, 6" x 1'4" (15 x 40 cm) beams or equal), a minimum of 6" (15 cm) above ground level to reduce humidity and pro- tect the unit against possible water damage and decreased service life. (Figs. 5b and 5c)

NO

 

Exhaust fan

 

Hot air

Heat source

Outdoor unit

Fig. 4

Obstacle above

*3

 

 

 

 

 

Air intake A

 

 

discharge

B

C

*2

Min. 10"

*4

 

 

(25 cm)

Air

 

Obstacle

Min.

Min.

 

 

6" (15 cm) Air discharge

 

 

CAUTION

A solid base must not cover the hole of the bottom plate.

3'3" (100 cm)

 

*1

 

Ground

Min. 8" (20 cm)

install cushion rubber under unit’s feet to reduce vibration and noise. (Fig. 5d)

use lug bolts or equal to bolt down unit, reducing vibration and noise.

install in a location where no antenna of a television or radio exists within 10' (3 m).

Fig. 5a

Air intake

 

CAUTION

Drain holes

Fig. 5b

Concerning air-intake side distance “A” (Fig. 5a) The minimum for distance “A” is 6" if there are no obstructions on the air-discharge side (wall *1 side) and *2 or *4 is not present. In all other cases, the min- imum for distance “A” is 8".

If wall *1 is on the air-discharge side (Fig. 5a), or if obstructions are present on all 3 sides *2, *3, and *4 (Fig. 5a), then the minimum distance for “B” and “C” is 39-3/8". Even if there is no wall on the air-discharge side, a minimum of 39-3/8" is required.

Air intake

Concrete or equal

About

 

 

1'4"

(40

cm)

 

 

 

Anchor bolts (4 pcs.)

Min. 6" (15 cm)

6"

(15

cm)

 

 

 

About

Cushion rubber

(Locally purchased)

Fig. 5c

Fig. 5d

5

Page 78
Image 78