Sanyo C3682, C3082 service manual Charging Additional Refrigerant, Retro-Fitting Existing Systems

Models: C3082 C3682

1 104
Download 104 pages 14.11 Kb
Page 54
Image 54

10-7. Charging Additional Refrigerant

10-7-1. When Tubes are Extended

Observe the proper amount of refrigerant as stated in this service manual or the installation manual that came with the indoor unit. Charge additional refrigerant in liquid state only.

CAUTION

Never charge additional refrigerant if refrigerant is leaking from the unit. Follow instructions given in "10-6. In Case Refrigerant is Leaking" and completely carry out repairs. Only then should you recharge the refrigerant.

10-8. Retro-Fitting Existing Systems

10-8-1. Use of Existing Units

Never use new refrigerant R410A for existing units which use R22. This will cause the air conditioner to

operate improperly and may result in a hazardous condition.

10-8-2. Use of Existing Tubing

If replacing an older unit that used refrigerant R22 with a R410A unit, do not use its existing tubing. Instead, completely new tubing must be used.

54

Page 54
Image 54
Sanyo C3682, C3082 service manual Charging Additional Refrigerant, Retro-Fitting Existing Systems, When Tubes are Extended