Sanyo C3082 Self-diagnostics Lamps, Indoor Unit, OPERATION lamp, TIMER lamp, LED CLEAN lamp

Models: C3082 C3682

1 104
Download 104 pages 14.11 Kb
Page 37
Image 37

(1) Self-diagnostics Lamps

INDOOR UNIT

(1) OPERATION lamp

 

(2) TIMER lamp

OPERATION

TIMER

LED CLEAN

ON/OFF

(3) LED CLEAN lamp

Since the indications cover various units, the corresponding parts listed below may not be present in some models.

 

Indication on indoor unit

 

.... OFF

 

 

.... Blinking

.... ON (Illuminated)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm

LED Clean

Timer

Operation

Error

Diagnosis Contents

 

 

 

 

 

Possible Malfunction

 

Code

(3)

(2)

(1)

Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F10

 

 

 

S01

Room temperature sensor failure

(1)

Sensor open circuit or short circuit

 

 

 

 

 

 

 

 

 

 

 

(2)

Contact failure at connector or open circuit at terminal crimping location

F02

 

 

 

S02

Indoor heat exchanger sensor failure

 

 

 

 

(short-circuit detection only for the humidity sensor)

 

 

 

 

 

 

 

 

 

(3)

Indoor/outdoor PCboard failure

 

 

 

 

 

F13

 

 

 

S03

Humidity sensor failure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F04/F12

 

 

 

S04

Compressor temperature sensor failure

(1)

Sensor open circuit or short circuit

 

 

 

 

 

 

 

 

 

 

 

(2)

Contact failure at connector or open circuit at terminal crimping location

F09/

 

 

 

S05

Outdoor heat exchanger sensor failure

F15 to F18

 

 

 

(3)

Outdoor PCboard failure

 

 

 

 

 

 

 

F08/

 

 

 

S06

Outdoor air temperature sensor failure

 

 

 

 

 

 

 

 

 

 

 

 

 

F21 to F24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F27

 

 

 

S07

failureOutdoor electrical current detection

Outdoor PCboard failure

 

 

 

 

 

 

 

 

 

 

 

 

Indoor/outdoor communications failure

(1)

Mis-wiring

(2) AC power failure

(3) Blown fuse

(4) Power Relay failure

E05

 

 

 

E01

(5)

Indoor or outdoor PCboard failure

(6) Outdoor Fan Motor failure (7) Reactor failure

 

 

 

(serial communications)

(8)

High-Pressure Switch failure

(9) Overload Relay failure

(10) Magnetic Coil failure

 

 

 

 

 

 

* See detailed flowchart in this section.

 

 

 

 

P26

 

 

 

E02

• HIC circuit failure

(1)

HIC or power Tr failure (2) Outdoor fan does not turn.

(3) Instantaneous power outage

 

 

 

(4)

Service valve not opened.

(5) Outdoor fan blocked.

(6) Continuous overload operation

 

 

 

• Power Tr (transistor) circuit failure

 

 

 

 

 

 

(7)

Compressor failure

(8) Outdoor PCboard failure

 

 

 

 

F31

 

 

 

E03

failureOutdoor unit external ROM (OTP data)

(1)

External ROM data failure

 

(2) Outdoor PCboard failure

 

P16

 

 

 

E04

Peak current cut-off

(1)

Instantaneous power outage

(2) HIC or power transistor failure

 

 

 

(3)

Outdoor PCboard failure

 

 

 

 

 

 

 

P07

 

 

 

E05

• PAM circuit failure

(1)

Outdoor PCboard failure

(2) Outdoor power supply voltage failure

 

 

 

• Active circuit failure

P03

 

 

 

E06

Compressor discharge overheat

(1) Electric expansion valve failure

(2) Capillaries choked

(3) Shortage of refrigerant

 

 

 

prevention activated.

(4) Continuous overload operation

(5) Outdoor fan does not rotate

(6) Outdoor PCboard failure

P01

 

 

 

E07

Indoor fan operating failure

(1)

Fan motor failure

(2) Contact failure at connector

 

(3) Indoor PCboard failure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P19

 

 

 

E08

4-way valve switching failure

(1)

4-way valve failure (heat pump model only)

 

 

 

 

 

 

 

• Indoor zero-cross failure

(2)

Outdoor PCboard failure

 

 

 

 

 

 

 

P15

 

 

 

E09

No-refrigerant protection

(1)

Service valve not opened.

 

(2) Shortage of refrigerant

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P29

 

 

 

E10

DC compressor drive circuit failure

(1)

Open phase

(2) Outdoor PCboard failure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P22

 

 

 

E11

Outdoor fan operating failure

(1)

Fan motor failure

(2) Contact failure at connector

 

(3) Outdoor PCboard failure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E07/P04/P05

 

 

 

 

• Outdoor system communications failure

(1)

Mis-wiring

(2) Blown fuse

(3) Power Relay failure

 

(4) Outdoor PCboard failure

 

 

 

E12

• OLR operation

 

P20/P27

 

 

 

• Outdoor power supply open phase

(5)

Compressor failure

 

 

 

 

 

 

 

 

 

 

 

 

• Outdoor coil freezing

* See detailed flowchart in this section.

 

 

 

 

P11

 

 

 

E13

Freeze-prevention operation activated.

(1)

Indoor fan system failure

(2) Shortage of refrigerant

(3) Low-temperature operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

37

Page 37
Image 37
Sanyo C3082 Self-diagnostics Lamps, Indoor Unit, OPERATION lamp, TIMER lamp, LED CLEAN lamp, Blinking, ON Illuminated