ACTIVE RECORDING AND VIDEO LOSS SETTING

Menu 5

 

 

ACTIVE REC Settings ExamplesExample 1: Recording on the tape when an alarm trigger is received from camera 2

Camera 2 picture 02

(Normal)

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 01

(REC MODE: MODE1)

 

 

 

 

Alarm trigger in

 

 

 

 

 

Alarm trigger out

 

 

 

01

02

03

 

04

 

02

02

 

02

02

02

02

02

02

05

06

07

08

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm duration for camera 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(REC MODE: MODE2)

 

 

 

 

Alarm trigger in

 

 

 

 

 

 

 

Alarm trigger out

 

 

 

01

02

03

 

04

 

02

05

 

02

06

02

07

02

08

 

09

10

11

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal recording

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm duration for camera 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(no alarm trigger)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example 2: Recording on the tape when an alarm trigger is received from camera 4 when an alarm trigger has already been received from camera 2

Camera 2 picture

 

Camera 4 picture

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02

 

 

 

 

04

 

 

 

 

 

 

 

 

(Normal)

01

02

03

04

05

06

07

08

09

10

11

12

13

14

15

16

01

(REC MODE: MODE1)

 

Alarm trigger in

 

Alarm trigger in

 

 

Alarm trigger out

 

 

Alarm trigger out

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01

02

03

04

02

02

02

04

02

04

02

04

04

04

04

04

05

06

Alarm duration for Alarm trigger received from camera

camera 24 during the alarm duration for trigger from camera 2

Alarm duration for camera 2 is over, remaining alarm duration for trigger from camera 4

(REC MODE: MODE2)

 

Alarm trigger in

 

Alarm trigger in

 

 

Alarm trigger out

 

 

Alarm trigger out

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01

02

03

04

02

05

02

04

06

02

07

04

08

04

09

04

10

11

Alarm duration for Alarm trigger received from camera

camera 24 during the alarm duration for trigger from camera 2

Alarm duration for camera 2 is over, remaining alarm duration for trigger from camera 4

NOTE: The ACTIVE REC examples are given for function illustration purposes only. The actual recordings will vary according to the various settings.

34

English