SPECIFICATIONS

Signal format

: Based on NTSC color signal standard (MPX-CD162)

 

Based on NTSC B/W signal standard (MPX-MD162)

Camera signal input synchronization

: Asynchronous

Camera input terminals (IN)

: VS/VBS, 1.0 Vp-p/75 , BNC connector x 16

Camera output terminals (OUT)

: Throughput of each input, 1.0 Vp-p/75 , BNC connector x 16

VCR input terminal (VCR IN)

 

Composite input

: VS/VBS, 1.0 Vp-p/75 , BNC connector x 1

S-VHS input terminal (S-VIDEO VCR IN) : Separate YC signals, DIN connector (S terminal) x 1 (MPX-CD162 only)

Y signal: 1.0 Vp-p/75 , unbalanced, synchronous; C signal: 0.286 Vp-p/75 , unbalanced

VCR output terminal (VCR OUT)

Composite output

S-VHS output terminal (S-VIDEO VCR OUT)

:VS/VBS, 1.0 Vp-p/75 , BNC connector x 1

:Separate YC signals, DIN connector (S terminal) x 1 (MPX-CD162 only)

Y signal: 1.0 Vp-p/75 , unbalanced, synchronous; C signal: 0.286 Vp-p/75 , unbalanced

Monitor 1 output terminal (MONITOR OUT 1) : VS/VBS, 1.0 Vp-p/75, BNC connector x 1

Separate YC signals, DIN connector (S terminal) x 1 (MPX-CD162 only)

Y signal: 1.0 Vp-p/75 , unbalanced, synchronous; C signal: 0.286 Vp-p/75 , unbalanced

Camera live picture or VCR playback picture signal output: full screen, sequential display, Multi-display screen

Monitor 2 output terminal (MONITOR OUT 2) : VS/VBS, 1.0 Vp-p/75, BNC connector x 1

 

 

Camera live picture signal output: full screen (can be set in (MONITOR SET) menu

 

 

to display the same image as monitor 1)

Control terminal (CONTROL)

 

Alarm input

: No voltage, make-contact switch input x 16 (Low input)

Sensor alarm output

: Alarm output x 16 (low output, normally open (NO))

Remote input (R1, R2)

: 2-wire type with resistance-based identification system

Alarm output (A)

: DC 5 V, 5.7 k(Low output)

Switching input (S)

: Low input, for input signal from SW OUT of timelapse VCR/real time recorder (as

 

 

per this manufacturer specifications)

RS485 control terminal

RS-232C terminal

Full screen sequence timing Monitor on-screen display Menu settings

:RJ-11 type: 2 terminals (A/B), Push-lock type: 3 terminals (A, B, GND)

:9-pin D-SUB

:Available in full screen mode, with interval selectable from 1 – 30 sec.

:Title (up to 10 characters), date, time selectable

:10 menus: Language, Clock, VCR, Alarm, Active REC, Monitor, Camera, Position, Display, Alarm data

Alarm sensor

: Internal, 16 channel (each camera input, selectable)

Back-up function

: Back-up for up to 30 days of the clock settings after connected for 30 hours

 

 

continuously

Operations

 

Still

: Available for camera live or VCR playback in full screen and zoomed in picture

 

Can be set using a menu to operate automatically when there is an alarm trigger

2x zoom

: Available for camera live or VCR playback in full screen and frozen picture

 

 

In full screen mode can switch from frozen to zoomed in picture

Power

: AC 120 V, 60 Hz

Consumption

: 20 W (MPX-CD162), 18 W (MPX-MD162)

Operating environment

: Temperature: 5 to 40˚C, Humidity: 10 to 80%

Dimensions

: 420 (W) x 86 (H) x 325 (D) mm

Weight

: Approx. 4.1 kg

Products are subject to change in design and specifications without notice and without incurring any obligation.

English

53