INTERFACE SPECIFICATIONS

SETTING THE DIP SWITCHES

 

COMMANDS

 

 

 

The DIP switches need to be set when a computer, special controller, etc. connected to the RS-232C or RS-485 connectors is used to control the multiplexer. Make sure to turn the multiplexer power off before setting the DIP switches.

 

 

 

 

(ADDRESS SET)

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

RS485

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

1

2

3

4

5

6

7

8

 

 

10

 

 

 

 

 

 

 

 

 

9

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TERMINATER ON/OFF

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS232C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW No.

1-7:To setup the multiplexer address (only when using the RS-485 connector).

Switch 1 is the least significant bit (LSB) and switch 7 the most significant bit (MSB) (Down: 0, Up: 1)

8:Open (not used)

9:To select the connector used. [232] side (down) for RS-232C, [485] side (up) for RS-485.

10:To setup the termination (only when using the RS-485 connector).

OFF side (down): Not terminated

ON side (up): Terminated

RS-232C exclusive use

1.Set the DIP switch 9 down ([232] position).

RS-485 exclusive use

1.Set the address using DIP switches 1 to 7.

Example:

If the address is 1, set switch 1 to the ON side (up)

If the address is 10, set switches 2 and 4 to the ON side (up)

If the address is 127, set all the switches to the ON side (up)

2.Set the DIP switch 9 up ([485] position).

3.Set the terminator using DIP switch 10

English

COMMANDS AVAILABLE FROM THE COMPUTER

1-16 (90-9F)

To select the picture from a camera to be displayed full screen on monitor 1.

MULTI (82)

To display a 16 or 9 divisions split screen on monitor 1.

QUAD (83)

To display a 4 divisions split screen on monitor 1.

PLUS (84)

To display a 13 or 6 divisions split screen on monitor 1.

SEQUENCE (87)

To switch the display mode from full screen to sequential display on monitor 1.

ZOOM (85)

To zoom in the picture on monitor 1.

STILL (86)

To freeze the picture on monitor 1.

LIVE (80)

To select the live input mode.

VCR (81)

To select the VCR playback input mode.

MON2 (88)

To set the output at monitor 2, it can be used in combination with the monitor 1 display.

MENU (74)

To display the menu on monitor 1.

+ (65), – (66)

To select settings (ON/OFF, numbers, letters, symbols) in the menus.

j(54), l (64), c (63), d (53)

To change selection in the menus. (To move the cursor up/down, right/left.)

NEXT (75)

To select the sub-menu in (SENSOR SET) and (DISPLAY SET) menus.

EXIT (76)

To go to the next menu, or to exit the menu mode.

MENU RESET (E1)

To reset all the values of the displayed menu to the default values.

CLOCK ADJUST (E0)

To reset the clock minutes and seconds setting to 00:00.

SECURITY LOCK ON (69)

To set the security lock.

SECURITY LOCK OFF (6A)

To cancel the security lock.

49