MONITOR SETTINGS

Menu 6

You can set the automatic sequential display speed on each monitor and the display sequence order. Also, you can have the live and/or recorded picture from certain cameras masked so that they are not visible on-screen.

(MONITOR SET)

Setting the Monitor Display

1 Press the MENU button 6 times to display the (MONITOR SET) menu.

2 Press the l button to highlight the setting to modify.

Using the + (or –) button, select the desired setting, then press the l button.

Following this procedure, select the settings or MON1 SEQ. TIMER ... COLOR LEVEL.

3 Press the MENU button to go to the next menu screen, or

Press the EXIT button to exit the menu display.

2

(MONITOR SET)

MON2 SEQ.MODE (Default setting: MODE1)

MODE1: The cameras are displayed full screen sequentially in order (1 to 16).

MODE2: The cameras are displayed sequentially in the order set in the (POSITION SET) menu, when the 16 cameras are displayed in a 16 divisions screen (see page 43).

MON2MON1 (Default setting: OFF)

ON: The display on monitor 2 will be the same as the one on monitor 1.

OFF: The display mode on monitor 2 will an automatic sequential display or full screen display of live pictures.

MON.MASK LIVE (Default setting: ON)

ON: If, for certain cameras, in the (CAMERA SET) menu, the “MON.MASK” item is set to “ON”, the live picture from those cameras will not be visible on-screen.

MON1 SEQ.TIMER

1

S

 

MON2 SEQ.TIMER

1

S

 

QUAD SEQ.TIMER

1

S

MON1 SEQ.MODE

MODE1

MON2 SEQ.MODE

MODE1

MON2 í MON1

OFF

 

 

MON.MASK LIVE

ON

 

 

MON.MASK VCR

ON

 

 

COLOR LEVEL

AUTO

 

 

 

 

 

 

MONITOR SET menu

MON1 SEQ.TIMER (Default setting: 1 S)

To set the full screen automatic sequential display speed (interval) on monitor 1.

The available intervals are: 1 – 30 seconds, INDIV.

MON2 SEQ.TIMER (Default setting: 1 S)

The available intervals are: 1 – 30 seconds, INDIV.

NOTE: If the “INDIV.” setting is used, in the (CAMERA SET) menu, enter the desired setting for each camera (see page 36).

QUAD SEQ.TIMER (Default setting: 1 S)

To set the 4 divisions screen automatic sequential display speed (interval).

The available intervals are: 1 – 30 seconds

MON1 SEQ.MODE (Default setting: MODE1)

MODE1: The cameras are displayed sequentially in order (1 to 16).

MODE2: The cameras are displayed sequentially in the order set in the (POSITION SET) menu, when the 16 cameras are displayed in a 16 divisions screen (see page 43).

OFF: The live picture from all cameras will be visible on-screen regardless of the “MON.MASK” item setting of each camera, in the (CAMERA SET) menu.

MON.MASK VCR (Default setting: ON)

ON: If, for certain cameras, in the (CAMERA SET) menu, the “MON.MASK” item is set to “ON”, the recorded picture from those cameras will not be visible on-screen.

OFF: The recorded picture from all cameras will be visible on-screen regardless of the “MON.MASK” item setting of each camera, in the (CAMERA SET) menu.

NOTE: The individual monitor masking setting is entered for each camera in the (CAMERA SET) menu (see page 36).

COLOR LEVEL (Default setting: AUTO)

AUTO: In divided screen display mode, the colors will be adjusted automatically.

If in divided screen mode the colors depth changes and the image is not clear, press the + or () button to select the desired level.

The available settings are:

1, 2, 3, 4, 5, AUTO, 5, 6, 7, 8, 9 (A higher number will set the colors to a depth setting.)

NOTE: Model MPX-MD162 does not have COLOR LEVEL function.

English