Connect the AC power cord to the projector and turn on the projector.
Turn off the projector and unplug the AC power cord. Let the projector cool for at least 45 minutes.
Remove the screw that secures the lamp cover, and then open the lamp cover.
Remove the two (2) silver screws that secure the lamp. Lift the lamp out of the projector by using the handle.

Maintenance and Filter Cleaning

Lamp Replacement

When the projection lamp of the projector reaches its end of life, the Lamp replacement icon appears on the screen and LAMP REPLACE indicator lights yellow. Replace the lamp with a new one promptly. The timing when the LAMP REPLACE indicator should light is depending on the lamp mode.

WARNING:

TURN OFF THE UV LAMP BEFORE

OPENING THE LAMP COVER

Top Control

LAMP REPLACE indicator

Lamp replacement icon

CAUTION CAUTION

Allow a projector to cool for at least 45 minutes before you open the Lamp cover. The inside of the projector can become very hot.

For continued safety, replace with a lamp of the same type lamp. Do not drop the lamp or touch the glass bulb! The glass can shatter and may cause injury.

Follow these steps to replace the lamp.

1

2

3

4 Replace the lamp with a new one and secure the two

(2)screws. Make sure that the lamp is set properly. Put the lamp cover back and secure it with the screw.

Screw

Handle

5

6 Reset the lamp replacement counter.

See “Lamp Replacement Counter” on the next page .

Silver Screws

ORDER REPLACEMENT LAMP

Replacement lamp can be ordered through your dealer. When ordering, give the following information to the dealer.

Model No. of your projector

: PLC-XT25/PLC-XT20

Replacement Lamp Type No. : POA-LMP105

(Service Parts No. 610 330 7329)

65

Page 65
Image 65
Sanyo PLC-XT25 owner manual Lamp Replacement, Reset the lamp replacement counter