Basic Setting and Operation
Examples: Type and contents of alert mail
When the projector has an abnormality, the following alert messages are sent to the registered
The following are examples of received messages.
●When the internal temperature is too high:
TITLE: Message from projector
Projector Model Name: XP41/XP46
TCP/IP: 192.168.0.2 Projector Name: myProjector
It sends you following massage.
*The Projector lamp is turned off, because internal projector temperature is too high.
Wait Temperature Warning Indicator turned off,turn the Projector on again. If the Indicator continues to flash,check the air filter for dust accumulation.
[A]36.5 Degree [B] 46.5 Degree [C] 58.2 Degree Temperature of Sensor C is too high.
✐The
●When the internal power circuit is failed:
TITLE: Message from projector
Projector Model Name: XP41/XP46
TCP/IP: 192.168.0.2 Projector Name: myProjector
It sends you following massage.
*The Projector lamp was turned off, because projector power circuit failed. Unplug the projector from AC outlet and ask servicing to qualified service personnel.
✐The Projector lamp was turned off, because the projector power circuit failed.
Unplug the projector from AC outlet and ask servicing to a qualified service personnel.
●When the life span of lamp is reached:
TITLE: Message from projector
Projector Model Name: XP41/XP46
TCP/IP: 192.068.0.2 Projector Name: myProjector
It sends you following massage.
*The life span of lamp is reached.
✐Replace it with a new lamp immediately and reset the lamp counter. If the projector is used without reset the lamp counter, the alert mail is sent to users in every power- on of the projector. This alert mail will not be sent when unchecking the mail sending condition "When the life span of lamp is reached".
32