Serial port setting
Serial port setting
Set up the extra serial port of this product. Click on the Extra Serial Port Setting linked text on the main menu and the following setting page will be displayed. To communicate with external equipment correctly, software communication conditions must be set to the same values as that the connected equipment is using. After fixing the setting, press the Set button*1. Enter your note into the comment column and press the Save button.
Setting Items | Description |
Baud Rate | Communication speed for serial port, select with popup menu button. |
Parity | Parity check, the ways for errors detecting of transferred data. |
Stop | Stop bit, indicates the end of communication. |
Flow Control | Ways for communication flow. |
Data | Indicates the length of data. |
Port | Indicates the port number of TCP/IP. The default number is 23. Use the |
| same port number specified by application. There are some reserved port |
| number*2. If one of those port numbers is used, the alert dialog window will |
| appear and let you know that it is an invalid port number. |
|
|
*1 This product will logout and restart automatically when the port number is changed and it takes about 40 seconds.
*2 The reserved port numbers are http (80), ftp (21), telnet (23), etc.