Chapter 3 Basic Setting and Operation
Examples: Type and contents of alert mail
When the projector has an abnormality, the following alert messages are sent to the regis- tered
The following are examples of received messages.
●When internal PJ temperature is too high:
TITLE: Message from projector |
|
Projector Model Name: model name |
|
TCP/IP: 192.168.1.201 Projector Name: Proj05 | |
|
It sends you following message.
*The projector lamp is turned off, because internal temperature goes over the safety limit. Wait for the completion of the cooling process and make sure the projector has been turned into Standby. Then turn the projector on again.
If the Indicator continues flashing, check the air filter for dust accumulation.
●When PJ needs service:
*Maintenance requirement from Projector is detected.
Check up LED status of projector and consult with the dealer.
AD, | 3.3V | OK |
| |
KS, | 3.3V | OK |
| |
| ||||
MAIN, | 3.3V | NG | Error information | |
|
✐The projector lamp was turned off, because the projector power circuit failed.
Unplug the AC power cord and plug it, and then turn on the projector once again to verify operation. If the problem still persists, unplug the AC power cord and ask servicing to a qualified service personnel with the error information.
●When PJ lamp replacement time is reached:
*The projector lamp 1 has reached replacement time. Lamp 1 ON 2000 h
Lamp 2 ON 1800 h
✐Replace it with a new lamp immediately and reset the lamp counter. If the projector is used without resetting the lamp counter, the alert mail is sent to users in every power- on of the projector. This alert mail will not be sent when unchecking the mail sending condition "When PJ lamp replacement time is reached".
●When the brightness (Current value) continuously goes down a certain rate from Target value in Constant mode:
*The brightness (Current value) continuously goes down a certain rate from the value in Constant mode. Check the lamp status and replace the lamp, or decrease Target value in Constant mode.
✐This alert mail will be sent when "Lamp mode" is set to "Constant mode".
28