OUTPUT TERMINALS

TAPE END OUT Terminal

œDuring recording, when the end of the tape is reached
or when the tape counter reading indicates 1 hours 57
minutes or more, the output becomes 0V (Low).
œTo reset the output, press the STOP or EJECT button.
œDuring autorepeat recording, when the end of the tape
is reached, the output becomes 0V (Low) for about 2
seconds only.
TAPE END OUT Terminal Output Setting
1Press the MENU button until the (SET UP 3) menu is
displayed.
@@@@@@@<SET@UP@3>
öALARM@MODE@@@@@@@Y1
öALARM@DURATION@@@20S
öEXT@TIME@ADJ.@@@@01:00
öTAPE@IN@MODE@@@@@STOP
öTAPE@END@MODE@@@@REW
öTAPE@END@OUT@@@@@-3M
öCLOG@DETECT.@@@@@Y
öSERIES@REC@IN@@@@N
öRS-232C@@@@@@@@@@19200
2Turn the JOG dial, until the “TAPE END OUT” setting
is flashing.
3Turn the SHUTTLE ring, to select the desired output
mode.
–3M . . . . . . . The output becomes 0 V (Low)
when the tape counter reaches
“1H57M00S” and/or when the tape
reaches the end.
END. . . . . . . The output becomes 0 V (Low)
when the tape reaches the end.
4Press the SEARCH/AUDIO ON button to save the
setting.

WARNING OUT Terminal

œIf the tape stops or other problem, the output becomes
0V (Low).
œTo reset the output, press the STOP or ALL RESET
button or unplug the power cord then plug it back in.
NOTE:
œIf the output is 0V (Low) due to the clog detect function,
it can be reset by simply pressing the STOP button.

TIMER OUT Terminal

œDuring timer recording DC 12 V (High) are output.
(During timer recording stand-by mode, the output is
0V (Low).)

COM Terminal

œCommon GND (ground) terminal when connecting
other terminals to external devices.
Tape end or 1
H
57
M
00
S
5V (H)
0V (L)
(Output impedance: 5.7 k)
Output reset
Tape movement stop
5V (H)
0V (L)
(Output impedance: 5.7 k)
Output reset
Timer recording
12V (H)
0V (L)
(Output impedance: 5.7 k)
RC4Q/U (TLS-9960 GB) Mon. Aug., 23/1999