− 12 −

[4] Command List (Query) for MD800-500

Message

 

 

 

Query Command

 

 

 

 

 

Response Command

 

 

Zoom

Tele/Wide Speed

80

02

08

CS

FF

C0

02

08

0p

CS

FF

 

 

 

Configured Tele/Wide Speed

1: speed1, 2: speed2, 3: speed3, 4: speed4

 

Direct

80

02

09

CS

FF

C0

02

09

0p

0q

0r

CS

FF

 

Current Zoom Lens Position

Direct Position 0:Wide 2263:Tele

 

Digital Zoom Tele Limiter

80

02

18

CS

FF

C0

02

18

0p

CS

FF

 

 

 

Current Digital Zoom Limit

 

 

V-Reso.UP OFF/ON

80

02

1F

CS FF

C0

02

1F

0p

CS

FF

 

 

 

 

 

Focus

Far/Near Speed

80

03

08

CS

FF

C0

03

08

0p

CS

FF

 

 

 

Configured Far/Near Speed

1: speed1, 2: speed2, 3: speed3, 4: speed4

 

Direct

80

03

09

CS

FF

C0

03

09

0p

0q

0r

CS

FF

 

Current Focus Lens Position

Direct Position 0:Far 1209:Near

 

Near Limiter

80

03

0E

CS

FF

C0

03

0E

0p

CS

FF

 

 

 

 

 

 

Auto Focus Sensitivity

80

03

10

CS

FF

C0

03

10

0p

CS

FF

 

 

 

 

 

 

Focus Area

80

03

13

CS FF

C0

03

13

0p

CS

FF

 

 

 

 

 

 

Cover Offset OFF/ON

80

03

15

CS

FF

C0

03

15

0p

CS

FF

 

 

 

Offset ON/OFF setting when using the cover

p: 0:OFF, 1:ON

 

Cover Offset Level

80

03

16

CS

FF

C0

03

16

0p

0q

CS

FF

 

 

Offset level setting when using the cover

pq: 0 100

 

Auto Focus Mode during

80

03

1F

CS

FF

C0

03

1F

0p

CS

FF

 

 

 

Auto focus mode setting during Pan/Tilt

p: 0:AF, 1: Fixed

 

pan/tilt

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

White

MWB Red Direct

80

04

13

CS

FF

C0

04

13

0p

0q

CS

FF

 

 

MWB R Component Set Value

Direct 0-255

Balance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MWB Blue Direct

80

04

1D

CS

FF

C0

04

1D

0p

0q

CS

FF

 

 

MWB B Component Set Value

Direct 0-255

 

ATW Smart OFF/ON

80

04

06

CS FF

C0

04

06

0p

CS

FF

 

 

 

 

 

 

WB Mode

80

04

07

CS FF

C0

04

07

0p

CS

FF

 

 

 

 

 

Iris

Iris Level Direct

80

05

13

CS

FF

C0

05

13

0p

0q

CS

FF

 

 

Iris Level Set Value

Direct 0-100

 

Iris Stop Direct

80

05

1D

CS

FF

C0

05

1D

p

CS

FF

 

 

 

Iris Aperture Set Value

1-17

Blc

Multi BLC Weight Direct

80

06

06

CS

FF

C0

06

06

0p

CS

FF

 

 

 

 

 

 

Multi BLC Bright Direct

80

06

09

CS

FF

C0

06

09

0p

CS

FF

 

 

 

 

 

 

Center BLC Weight Direct

80

06

10

CS FF

C0

06

10

0p

0q

0r

0s

CS FF

 

 

 

Center BLC Area Direct

80

06

13

CS

FF

C0

06

13

0p

0q

0r

0s

CS

FF

 

 

Shutter

Shutter Speed Set Mode

80

07

0E

CS

FF

C0

07

0E

0p

CS

FF

 

 

 

 

 

 

Shutter Long Direct

80

07

11

CS

FF

C0

07

11

0p

CS

FF

 

 

 

 

 

 

Shutter Short Direct

80

07

12

CS

FF

C0

07

12

0p

CS

FF

 

 

 

 

 

 

Sense Up Direct

80

07

1D

CS

FF

C0

07

1D

0p

CS

FF

 

 

 

 

 

Motion

Motion Size Direct

80

08

06

CS

FF

C0

08

06

0p

0q

CS

FF

 

 

 

 

 

Sensitivity Move Direct

80

08

1D

CS

FF

C0

08

1D

0p

CS

FF

 

 

 

 

 

 

Sensitivity Y-Level Direct

80

08

27

CS FF

C0

08

27

0p

CS

FF

 

 

 

 

 

 

Sensitivity Y-Differ Direct

80

08

31

CS FF

C0

08

31

0p

CS

FF

 

 

 

 

 

 

Sensitivity Duration Direct

80

08

3B

CS FF

C0

08

3B

0p

CS

FF

 

 

 

 

 

 

Motion Zoom

80

08

3D

CS FF

C0

08

3D

0p

CS

FF

 

 

 

 

 

 

Motion Interval

80

08

42

CS

FF

C0

08

42

0p

CS

FF

 

 

 

 

 

CS: Checksum

FF: Terminator

Communications Protocol

Model: VCC-MD800/700/600/500

Page 13
Image 13
Sanyo VCC-MD500, VCC-MD400P, VCC-MD300P, VCC-MD800P, VCC-MD600P, VCC-MD700 Command List Query for MD800-500, Cs Ff