Sanyo VCC-MD600P, VCC-MD400P, VCC-MD500, VCC-MD300P, VCC-MD800P, VCC-MD700 Backlight Compensation

Models: VCC-MD500P VCC-MD400 VCC-MD300 VCC-MD400P VCC-MD800 VCC-MD600P VCC-MD600 VCC-MD700 VCC-MD800P VCC-MD300P VCC-MD500 VCC-MD700P

1 42
Download 42 pages 30.54 Kb
Page 31
Image 31

Function Descriptions

Auto Iris (SENSE UP OFF) Diagram 1

Auto Iris (SENSE UP ON) Diagram 2

Max

Max

AGC Gain

AGC Gain

High Sensitive Photograph

0dB

 

0dB

 

 

open

Lens

open

Lens

 

 

Aperture

 

Aperture

 

close

 

close

 

 

Slow

 

Slow

 

 

 

 

 

Electronic Shutter

 

 

Electronic Shutter

 

(Fixed at 1/60 or 50)

Prolonged Exposure

 

(Optional)

 

 

 

 

 

 

 

 

Fast

 

Fast

 

 

 

Subject is dark

 

 

Subject is dark

Manual Iris (EI OFF) Diagram 3

Manual Iris (EI ON) Diagram 4

Max

 

Max

 

 

 

AGC Gain

 

AGC Gain

 

0dB

 

0dB

 

 

open

 

open

 

 

 

OFF

 

 

OFF

 

Lens Aperture (Optional)

 

Lens

 

 

 

 

Aperture

 

close

IRIS

close

(Optional)

 

 

 

 

 

 

 

Slow

 

Slow

 

OFF

 

Electronic Shutter (Optional)

 

 

 

 

 

 

Electronic Shutter

Fast

 

Fast

 

 

 

Subject is dark

 

 

Subject is dark

[7] Backlight Compensation

Multi-Area Light Measuring

This automatically detects the subject area, the backlight conditions, and automatically corrects the backlight.

The following settings configure sensitivity and the effectiveness of corrections when there is backlight.

BLC Weight

The sensitivity to backlight can be configured to a range of 0 to 15.

Larger values increase the sensitivity to backlight.

BLC Bright

The target brightness value of the subject area when there is backlight can be configured to a range of 0 to 15.

Larger values increase the effectiveness of the correction.

Center-weighted metering

The 48 total areas are divided into 5 and brightness levels are corrected by weighting and calculating each area.

The weight of each area can be configured to a range of 0 to 7. (CENTER is fixed at 7.)

The CENTER position and size can be changed according to the position of the subject.

BLC Mask

By specifying masked areas within the 48 total areas, brightness information of the masked areas is ignored and brightness levels are corrected.

Note: When the Day/Night switch control is set to AUTO mode, the backlight cannot be corrected with multi-area light measuring when the camera is set to B/W.

− 30 −

Page 31
Image 31
Sanyo VCC-MD600P, VCC-MD400P, VCC-MD300P, VCC-MD800P, VCC-MD700P, VCC-MD500P technical manual Backlight Compensation