Communications Protocol

Model: VCC-MD800/700/600/500/400/300

Note 4 Orientation / angle display

The display angle is changed using Pan/Tilt Degree commands.

The Set North command sets the current position to N and the pan degree to 0.

Pan angle versus orientation is as follows.

N337.6-22.5

NE 22.6-67.5

E67.6-112.5

SE 112.6-157.5

S157.6-202.5 SW 202.6-247.5

W 247.6-292.5 NW 292.6-337.5

Note 5 How to set the Camera ID and Title

Detailed settings of Camera ID and Title settings are as follows.

Set 8 (16) characters in ASCII code.

Transmit eight (16) characters at the time in order starting with the first character. The following characters may be used.

*The following value (HEX) is also answered as response command to a query command.

*No Title settings are available for models MD400, MD300.

*The numbers within the brackets refer to the VCC- MD400 and MD300 models

Note 6 Rom Version display

No command other than the Version display ON/OFF command will be received during Version display. No OSD other than the Version OSD is displayed during Version display.

The display will be erased 3 minutes after the ON command is sent.

Note 7 ATW Smart exclusion processing

In models MD-300, 400 the Onepush Trigger by Onepush Trigger (AWC set) command is not available when setting the ATW Smart.

Before issuing an AWC set command set the ATW Smart to OFF.

If setting the ATW Smart to ON again, do so once the Onepush Trigger operation is complete (3 seconds) or right before sending the ATW command.

Note 8 Pxel defect compensation

When pixel defect compensation function has been executed by command, command transmission cannot be done during the period described below (not sending either ACK/NACK/ERR) :

MD600(P), MD500(P): 15 seconds

MD800(P), MD700(P): 20 seconds

Note 9 Pan/Tilt angle setting

Due to optimization on controlling Auto Focus and

Character

Code

(HEX)

(Blank)

32

20

-

45

2D

0

48

30

1

49

31

2

50

32

3

51

33

4

52

34

5

53

35

6

54

36

7

55

37

8

56

38

9

57

39

:

58

3A

A

65

41

B

66

42

C

67

43

D

68

44

E

69

45

F

70

46

G

71

47

Character

Code

(HEX)

H

72

48

I

73

49

J

74

4A

K

75

4B

L

76

4C

M

77

4D

N

78

4E

O

79

4F

P

80

50

Q

81

51

R

82

52

S

83

53

T

84

54

U

85

55

V

86

56

W

87

57

X

88

58

Y

89

59

Z

90

5A

Privacy Masks, send same coordinate data at least twice when Pan/Tilt remain stationary.

Note10 Method of model distinguishing

 

5th digit in version

bit5 of 3rd byte in status

 

info

command

VCC-MD800(P)

5

1

VCC-MD700(P)

5

0

VCC-MD600(P)

4

1

VCC-MD500(P)

4

0

Version Query Command: 80 4A 0A CS FF Version Response Command:

C0 4A 0A 0p 0q 0r 0s 0t 0u

0v 0w CS FF

x365

x304

Status Command: 80 4A 01 CS FF Status Response Command:

C0 4A 01 p q r s t u CS FF

0 b6 b5 b4 b3 b2 b1 b0

D/N 1

Color0

− 25 −

Page 26
Image 26