3. Electrical data

3-2 Outdoor Unit

1 CH2432

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Terminal

 

 

 

 

• Schematic Diagram

 

 

CR-CH2432

(U1) (U2)

Plate (5P)

 

 

 

 

 

 

 

 

 

63PH

 

 

Controller

-1

 

 

1

 

 

 

 

 

 

 

 

 

 

2P-1

2P-2

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-2

 

 

F1(3A)

 

RY3

 

 

RY1

RY2

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

1Y

 

 

CN2

 

 

 

63PH

 

 

 

 

 

 

 

 

 

 

2

 

-G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RY4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

PRY

 

 

 

 

 

 

H

 

LL

20S

 

52C

 

 

AC 208V

 

 

 

 

 

 

 

 

 

 

 

3

230V

 

 

 

 

 

3

5

 

3

 

3

7

 

 

 

 

-L1

 

 

 

 

 

 

 

 

 

 

49

 

 

 

 

TR

 

 

 

 

 

 

 

 

 

 

FO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-L2

 

 

 

 

 

 

 

 

 

 

 

 

 

SEC

2

 

 

 

 

 

 

 

 

2

 

 

3

 

 

AC 14V

 

 

 

52C

 

 

 

 

 

 

RY1

20S

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor

1

TH6

 

 

 

 

 

 

 

 

 

 

 

49FO

RY2

52C

 

 

 

 

1

 

5

6

 

7

 

 

Coil C1

2

 

 

 

 

 

 

 

 

 

 

 

 

CT

 

 

 

 

H

M

L

20S

 

 

4

 

 

 

 

TH7

 

 

 

 

 

 

 

 

 

 

RY3

FM1

Outdoor

1

 

 

 

 

 

 

 

 

 

 

 

 

52C

 

 

CH

1Y

FMO

 

 

 

 

 

Coil C2

2

 

 

 

52C

 

RY4

FM2

 

1

TH8

 

 

 

 

 

 

 

 

 

 

 

 

Discharge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

1

2

1

 

 

9

 

 

Gas

2

 

 

 

PTC

 

 

 

 

 

DC12V

 

 

 

 

RC1

 

 

RC2

 

 

 

 

 

49

 

 

CT1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

C

R

S

 

 

 

 

 

 

 

 

 

 

 

N1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

1

1

 

1

 

 

 

 

 

 

 

CM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F2(3A)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Symbols

 

Description

 

 

 

 

Symbols

 

Description

 

 

CM

Compressor Motor

TH6

Thermistor (Outdoor Coil C1)

FMO

Outdoor Fan Motor

TH7

Thermistor (Outdoor Coil C2)

 

 

 

 

52C

Compressor Motor Magnetic Contactor

TH8

Thermistor (Discharge Gas)

 

 

 

 

49FO

Outdoor Fan Motor Thermal Protector

PTC

PTC Thermistor

 

 

 

 

63PH

High Pressure Switch

CR-CH2432

Outdoor Controller

 

 

 

 

CT

Current Transmitter

RY1~RY4

Auxiliary Relay

 

 

 

 

RC1, RC2

Running Capacitor

1Y

Auxiliary Relay

 

 

 

 

TR

Power Transformer

 

Terminal Plate

 

 

 

 

CH

Crank Case Heater

 

Terminal

 

 

 

 

20S

Four Way Valve

 

Connector

 

 

 

 

F1, F2

Fuse

 

 

S 854-2-5268-582-00-2 (CH2432)

Section

1

2

3

4

SM830076

– 49 –

Page 49
Image 49
Sanyo XHS2432, XHS3632, CH2432, CH3632 service manual Outdoor Unit, Controller

XHS3632, XHS2432, CH3632, CH2432 specifications

The Sanyo CH3632 is a cutting-edge air conditioning unit that exemplifies efficiency and innovation in climate control technology. Designed primarily for residential use, this model has attracted attention due to its combination of powering performance and user-friendly features.

One of the standout characteristics of the Sanyo CH3632 is its energy efficiency. With a high Seasonal Energy Efficiency Ratio (SEER), the unit consistently delivers cooling while minimizing energy consumption. This not only reduces monthly electricity bills but also contributes positively to environmental sustainability. Its environmentally friendly refrigerant further emphasizes Sanyo's commitment to eco-conscious designs.

The unit employs advanced inverter technology, which allows for variable-speed compressor operation. This means that instead of turning on and off, the compressor adjusts its speed based on the cooling needs of the space. This creates a more stable and comfortable indoor environment while ensuring quieter operation. The reduced noise levels make the CH3632 an excellent choice for bedrooms and living spaces where peace and tranquility are essential.

Another key feature of the Sanyo CH3632 is its dual filtration system, which combines a pre-filter with a HEPA filter. This system effectively captures dust, allergens, and other airborne particulates, ensuring that the air quality remains high. Homeowners can breathe easier knowing that their indoor air is cleaner and healthier.

Smart features are also integral to this model. The Sanyo CH3632 can be integrated with smart home systems, allowing users to control temperature settings via mobile apps or voice commands. This connectivity makes it convenient to manage cooling preferences from anywhere in the house, adding a layer of modern convenience to home comfort.

Installation of the Sanyo CH3632 is straightforward and can often be completed without extensive modifications to existing structures. Its sleek design allows it to blend seamlessly into various home aesthetics, making it an attractive addition to any space.

In summary, the Sanyo CH3632 is a highly efficient air conditioning unit that incorporates advanced technologies for optimal performance. With eco-friendly features, smart connectivity, and an emphasis on air quality, it sets a high standard for comfort in residential air conditioning solutions.