SETTING THE TIMER

1. How to set the present time

(Example) To set to 9:10 pm.

 

Operation

Indication

 

 

 

1.

Press the SET button three

The time indication alone

 

times.

flashes.

2.

• Press the HH button until

The display will flash for 10 sec.

 

PM 9 is displayed.

and automatically stop flashing

 

• Press the MM button until

except for the “ : ” symbol.

 

10 is displayed.

 

 

 

 

2. How to set the OFF time

(Example) To stop the air conditioner at 11:30 pm.

OFF TIME

Present time

 

 

Operation

Indication

1.Press the SET button twice. The timer indication alone flashes and the previous set- time is only displayed.

2.

• Press the HH button until

The display will change

 

 

PM 11 is displayed.

automatically back to show the

 

• Press the MM button until

present time after about 10 sec.

 

30 is displayed.

 

 

3.

Press the TIMER SELECT

The present time and

are

 

button twice to set OFF time.

displayed.

 

To cancel the setting, press the TIMER SELECT button twice.

3. How to set the ON time

(Example) To start operation at 7:10 am.

 

ON TIME

 

 

Present time

 

 

 

 

 

 

 

 

Operation

 

Indication

 

 

 

 

 

 

 

 

1.

Press the SET button once.

The timer

 

indication alone

 

 

 

flashes and the previous set-

 

 

time is only displayed.

 

 

2.

• Press the HH button until

The display will change

 

 

 

AM 7 is displayed.

automatically back to show the

 

• Press the MM button until

present time after about 10 sec.

 

10 is displayed.

 

 

 

 

 

3.

Press the TIMER SELECT

The present time and

 

are

 

 

button once to set ON time.

displayed.

 

 

 

 

 

 

 

 

 

 

 

To cancel the setting, press the TIMER SELECT button three times.

4. How to set daily ON/OFF repeat timer

(Example) To start operation at 7:10 am. and stop the air conditioner at 11:30 pm.

Present time

OFF TIME

ON TIME

 

 

Programmed

 

 

 

daily ON / OFF

9:10 pm.

7:10 am.

11:30 pm.

Present time

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

Operation

 

Indication

 

 

 

Set the timer ON/OFF times as

The present time PM 9:10 and

shown in 2 and 3.

 

are displayed.

 

 

 

 

 

 

To cancel the setting, press the TIMER SELECT button once.

NOTE

You can check the timer ON/OFF times after you have set them by pressing the SET button.

5. Backup function

Even if the main power supply to the unit is turned off, the remote controller will store the previous settings in its internal memory for up to 8 hours. If the power is not turned back on within 8 hours, the previous settings will be lost. In this case, the mode settings must be reset by the user.

8

OI-139-8-EG

 

Page 96
Image 96
Sanyo XMS0972, XMS1272 service manual Programmed, Daily on / OFF, 910 pm 710 am 1130 pm Present time

XMS1272, XMS0972 specifications

The Sanyo XMS0972 and XMS1272 are remarkable air conditioning units that blend efficiency with cutting-edge technology. Designed for residential and commercial spaces, these models promise comfort while optimizing energy consumption.

One of the standout features of both the XMS0972 and XMS1272 is their advanced inverter technology. This feature allows the units to adjust their cooling capacity based on the room's ambient temperature. As a result, the air conditioners can maintain a consistent temperature without the frequent on/off cycles associated with traditional units. This not only ensures a more stable climate but also significantly reduces energy consumption, making them eco-friendly options.

Another significant characteristic is the Quiet Operation mode. Both models are engineered with noise reduction technology, providing a tranquil environment for users. This is particularly beneficial for bedrooms, offices, or libraries where noise levels can be a concern. The XMS models operate at a whisper-quiet level, allowing users to focus on their tasks or enjoy a peaceful night's sleep without disruption.

The Sanyo XMS0972 and XMS1272 also feature a user-friendly digital interface. With an intuitive remote control and an easy-to-read display, setting your desired temperature or switching modes has never been easier. Moreover, the smart diagnostic capability allows for quick troubleshooting, helping to identify any issues to ensure peak performance throughout their lifespan.

Both models are equipped with a 24-hour timer, adding convenience for users who wish to come home to a pre-cooled or heated environment. This feature enhances comfort and saves energy when the unit is not in use.

In terms of design, the Sanyo XMS units boast a sleek and modern aesthetic that seamlessly integrates into various interior styles. Their compact size allows for flexible installation options, making them suitable for various living and working spaces.

The XMS line also emphasizes air purification, incorporating advanced filters that capture dust, allergens, and other pollutants. This results in not just temperature control but also improved air quality, contributing to a healthier living environment.

In conclusion, the Sanyo XMS0972 and XMS1272 air conditioning units stand out for their energy efficiency, quiet operation, user-friendly features, and air purification capabilities. These characteristics make them an ideal choice for individuals and businesses looking for reliable and sophisticated climate control solutions.