A. Installing with in-wall junction box

(1)

Install the junction box (locally purchased) into the wall.

 

(Figs. 2-a and 3)

(2)

Pass the wire harness through the junction box and

 

conduit. (Fig. 3)

(3)

Insert a flathead screwdriver into the 5 tab locations

 

and disconnect the back plate of the remote controller by

 

lifting up slightly. (Fig. 2-b)

 

The tabs are thin; take care not to chip them.

(4)

Pass the wire harness connector through the cord open-

 

ing on the back plate of the remote controller.

 

Use nippers or a similar tool to cut out the slots for the

In-wall junction box (locally purchased)

9/32"-3 (83.5mm)

3/16"-4 (106mm)

Tab

 

 

2-3/8"

Back

(60mm)

plate

Fig. 2-a

Fig. 2-b

from the indoor unit

 

remote controller back plate screws. Insert the spacers

 

and use the machine screws to install the remote con-

 

troller back plate. (Fig. 3)

(5)

Insert the connector into the PCB of the remote controller

 

unit, and wrap the wire harness around the hook. (Fig. 4)

(6)

Store the excess wire harness inside the junction box,

 

then hook the remote controller unit onto the top of the

 

back plate and install the remote controller unit.

(7)

To remove the remote controller unit after it has been

 

installed, insert a flathead screwdriver into the slot on the

 

bottom of the case and turn it. (Fig. 5)

B. Installing directly onto the wall

(1) Insert a flathead screwdriver into the 5 tab locations and

disconnect the back plate of the remote controller by lift-

ing up slightly. (Fig. 2-b)

The tabs are thin; take care not to chip them.

In-wall junction box

Opening

Wire harness

Back plate

Machine screws

Remote controller

Fig. 3

Wall

Spacers

(2)

Use tapping screws to directly fasten the remote con-

 

troller back plate onto the wall. (Fig. 6)

(3)

Insert the connector into the PCB of the remote controller

 

unit, and wrap the wire harness around the hook. (Fig. 4)

(4)

Use nippers or a similar tool to cut out the slot on the top

 

of the remote controller unit. Pass the wire harness

 

through the slot, then hook the remote controller unit

PCB

Hook

Connector

Slot

onto the top of the back plate and install the remote con-

troller unit.

(5) In order to conceal the exposed wiring, use a wire cover

(locally purchased) or similar means.

Fig. 4

Fig. 5

NOTE

When installing the remote controller back plate, be sure that it is flat and straight. Do not over-tighten the installa- tion screws.

Install the remote controller away from all sources of elec- trical noise.

Install a noise filter or take other appropriate action if elec- trical noise affects the power supply circuit of the unit.

Wire harness

Cut out

Wall

Back plate

Tapping screws

Remote controller

Fig. 6

2

Page 100
Image 100
Sanyo XMS0972, XMS1272 service manual Installing with in-wall junction box, Installing directly onto the wall

XMS1272, XMS0972 specifications

The Sanyo XMS0972 and XMS1272 are remarkable air conditioning units that blend efficiency with cutting-edge technology. Designed for residential and commercial spaces, these models promise comfort while optimizing energy consumption.

One of the standout features of both the XMS0972 and XMS1272 is their advanced inverter technology. This feature allows the units to adjust their cooling capacity based on the room's ambient temperature. As a result, the air conditioners can maintain a consistent temperature without the frequent on/off cycles associated with traditional units. This not only ensures a more stable climate but also significantly reduces energy consumption, making them eco-friendly options.

Another significant characteristic is the Quiet Operation mode. Both models are engineered with noise reduction technology, providing a tranquil environment for users. This is particularly beneficial for bedrooms, offices, or libraries where noise levels can be a concern. The XMS models operate at a whisper-quiet level, allowing users to focus on their tasks or enjoy a peaceful night's sleep without disruption.

The Sanyo XMS0972 and XMS1272 also feature a user-friendly digital interface. With an intuitive remote control and an easy-to-read display, setting your desired temperature or switching modes has never been easier. Moreover, the smart diagnostic capability allows for quick troubleshooting, helping to identify any issues to ensure peak performance throughout their lifespan.

Both models are equipped with a 24-hour timer, adding convenience for users who wish to come home to a pre-cooled or heated environment. This feature enhances comfort and saves energy when the unit is not in use.

In terms of design, the Sanyo XMS units boast a sleek and modern aesthetic that seamlessly integrates into various interior styles. Their compact size allows for flexible installation options, making them suitable for various living and working spaces.

The XMS line also emphasizes air purification, incorporating advanced filters that capture dust, allergens, and other pollutants. This results in not just temperature control but also improved air quality, contributing to a healthier living environment.

In conclusion, the Sanyo XMS0972 and XMS1272 air conditioning units stand out for their energy efficiency, quiet operation, user-friendly features, and air purification capabilities. These characteristics make them an ideal choice for individuals and businesses looking for reliable and sophisticated climate control solutions.