890 USE 103 00
4.Start your Borland compiler development environment as described in your compiler documentation
5.Update the BM85 Project file BM85PRJ to set the correct directory paths for your Borland environment For example, in the Borland
31 environment, you can use the following key sequence:
Key Sequence | Purpose |
|
|
Alt±P | Project open |
|
|
BM85.PRJ | Project name |
|
|
Alt±O D | Option directories |
|
|
(paths) | Update the paths for your INCLUDE and LIBRARY directories |
|
|
6.If either of these parameters is true, continue with Step 7 If neither is true, skip Step 7 and go to Step 8
h Your SA85/SM85 interrupt is set to a vector other than 5C h Your BM85 Modbus Plus node address is other than 4
7.Update the BM85LOAD and MBPSTIM command lines in the BM85 project's TRANSFER menu to use the new parameters In the Borland 31 environment, you can use the following key sequence:
Key Sequence | Purpose |
|
|
Alt±T | Transfer menu |
|
|
Select command line | Select the BM85 DOWNLOAD or MBPLUS STIMULATE line |
|
|
Alt±E | Edit |
|
|
Alt±C | Command line |
|
|
Enter parameters | Set the parameters as they are used in your application |
|
|
Alt±M | Modify |
|
|
Alt±K | OK |
|
|
8.When you have updated your project file, close the project In the Borland 31 environment, you can use the following key sequence:
Key Sequence | Purpose |
|
|
Alt±C | Project close |
|
|
Configuring the Programmable Models | 63 |