PowerLogicTM EM4800 Series

930-110-01-B.00

Installation

04/2011

 

 

If using a modem, these items are also required:

phone or butt set to test the phone line

RJ11 junction box

RJ11 splitter to tap into the existing junction box

RJ11 patch cable

xDSL filter if required (many businesses have their internet access on the same line as the fax)

Site Planning

1.

Determine the number of PowerLogic EM4800 series meters to be

 

 

installed and ensure adequate space. For clearances, see Figure 4 on

 

 

page 10.

 

2.

Determine the number of analog phone lines or Ethernet drops

 

 

required, and ensure they are installed before installing the PowerLogic

 

 

EM4833, EM4880 and EM4805 meters. The recommended maximum

 

 

number of PowerLogic meters per phone line is 50.

 

3.

Determine the number and types of meters or monitors required

 

 

(single-phase, network, or three-phase).

 

4.

Determine the model number and correct sense voltage based on the

 

 

voltage label on the top right side of the unit.

Access to Power and Lighting

The installation site must be supplied with access to the main electrical panel and any sub-panels. Portable or permanent lighting must be available to provide the installers with a clear view of the equipment and of the installation environment. Each installation may vary depending on physical site restrictions.

Installation Procedures

This section provides information about activities that must be performed to

 

install the PowerLogic EM4833, EM4880 and EM4805 meters in a

 

single-phase 2-wire, single-phase 3-wire (network), or three-phase 4-wire

 

application. The installation procedures must be performed in the following

 

order:

 

 

1.

“Mounting the PowerLogic EM4800 meter” on page 9

 

2.

“Installing Potential Transformers for Three-Phase Service Greater

 

 

Than 277V” on page 11

 

3.

“Installing the Sense Voltage and Control Voltage Cables in Wye and

 

 

Delta Services” on page 13

 

4.

“Installing the Current Transformers” on page 21

 

5.

“Connecting the Communications” on page 30

 

 

a.

“Connecting the Phone Line” on page 30

 

 

b.

“Connecting the Ethernet Cable” on page 30

 

 

c.

“Manually Testing Communications” on page 30

 

6.

“Start-Up Sequence” on page 30

 

7.

“Recording the Meter Map” on page 32

8

© 201 Schneider Electric All Rights Reserved

Page 14
Image 14
Schneider Electric E4800 manual Site Planning, Access to Power and Lighting

E4800 specifications

Schneider Electric's E4800 is a robust solution designed for comprehensive energy management, combining advanced features, innovative technologies, and user-friendly characteristics that cater to the needs of various industries. This device primarily focuses on enhancing efficiency in energy consumption and optimizing operational performance.

One of the standout features of the E4800 is its ability to monitor and manage energy consumption in real-time. This capability allows businesses to identify energy usage patterns, track costs, and gain insights into where energy can be saved. The real-time data analysis supports decision-making, enabling organizations to implement energy-saving strategies effectively.

The E4800 is equipped with an intuitive user interface that simplifies navigation and data interpretation. Users can access detailed analytics and reporting tools that provide visibility into energy performance metrics. This user-friendly aspect ensures that both technical and non-technical staff can utilize the system, fostering a culture of energy efficiency across the organization.

Additionally, Schneider Electric has integrated advanced communication technologies into the E4800. It supports various communication protocols such as Modbus, BACnet, and Ethernet, enabling seamless integration with existing systems and infrastructure. This versatility ensures that organizations can leverage their current investments in technology while upgrading to more advanced energy management solutions.

The E4800 is also designed with scalability in mind. Organizations can easily expand their energy management capabilities as their needs grow. Whether managing a single facility or a multi-site operation, the E4800 can adapt to varying requirements without significant overhauls or disruptions.

Another noteworthy characteristic is its compliance with global standards for energy management and sustainability. By utilizing the E4800, companies can demonstrate their commitment to environmental responsibility and adherence to regulations, which is increasingly important in today’s business landscape.

Lastly, Schneider Electric's E4800 comes with robust support services, ensuring that users can access assistance whenever needed. This commitment to customer service solidifies its position as a reliable solution for energy management.

In summary, Schneider Electric's E4800 offers a comprehensive suite of features designed for effective energy management, leveraging real-time analytics, versatile communication technologies, scalability, compliance with global standards, and excellent customer support, making it an ideal choice for businesses aiming to enhance their energy efficiency and sustainability.