Schneider Electric none manual From Routing Path, From Address Routing Method

Models: none

1 110
Download 110 pages 35.3 Kb
Page 33
Image 33

Here are examples of routing between peer￿ master￿ and slave devices.

From

To

Routing Path

CPU A (Primary)

Slave A

5

2

0

0

0

 

50

5

3

50

0

0

 

 

 

 

 

 

 

 

CPU C

25

2

0

0

0

 

 

 

 

 

 

 

 

SA85 (Task 1)

25

30

1

0

0

 

 

 

 

 

 

 

 

Slave B

25

4

2

0

0

 

 

 

 

 

 

 

 

200

25

4

3

200

0

 

 

 

 

 

 

 

CPU C

SA85 (Task 2)

30

2

0

0

0

 

 

 

 

 

 

 

 

Slave B

4

2

0

0

0

 

 

 

 

 

 

 

 

200

4

3

200

0

0

 

 

 

 

 

 

 

 

CPU A (Primary)

24

8

0

0

0

 

 

 

 

 

 

 

 

CPU B (Standby)

24

40

0

0

0

 

 

 

 

 

 

 

 

100

24

5

3

100

0

 

 

 

 

 

 

 

SA85

Slave B

4

2

0

0

0

 

 

 

 

 

 

 

 

150

4

3

150

0

0

 

 

 

 

 

 

 

 

CPU C

2

0

0

0

0

 

 

 

 

 

 

 

 

CPU A (Primary)

24

8

0

0

0

 

 

 

 

 

 

 

 

50

24

5

3

50

0

 

 

 

 

 

 

 

If Masters A￿ B￿ and C are programming panels such as the Modicon P230￿ they can attach to various devices using Direct￿ Implicit￿ or MUX addressing￿ or mapped routing:

From

To

Address

Routing Method

 

Master A

CPU A (Primary)

 

8

Attach

Direct

8

0

0 0

0

 

 

 

 

 

 

 

 

 

 

 

Slave A

 

72

Attach

MUX

Internal Path

 

 

 

 

 

 

 

 

 

 

CPU C

 

252

Attach

Implicit

252/10 = 25 2 0 0 0

 

 

 

 

 

 

 

 

 

 

 

 

 

50

 

50

Attach

Mapped

0

3

50 0 0

 

 

 

 

 

 

 

 

 

 

 

 

200

 

200

Attach

Mapped

25

4 3 200 0

 

 

 

 

 

 

 

 

 

 

 

 

 

Master B

CPU C

 

2

Attach

Direct

2

0

0 0

0

 

 

 

 

 

 

 

 

 

 

 

Slave B

 

72

Attach

MUX

Internal Path

 

 

 

 

 

 

 

 

 

 

CPU A (Primary)

 

248

Attach

Implicit

248/10 = 24 8 0 0 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200

 

200

Attach

Mapped

0

3

200

0

0

 

 

 

 

 

 

 

 

 

 

 

 

50

 

100

Attach

Mapped

24

5 3 50

0

 

 

 

 

 

 

 

 

 

Master C

CPU A (Primary)

 

248

Attach

Implicit

248/10 = 24 8 0 0 0

 

 

 

 

 

 

 

 

 

 

 

 

 

CPU B (Standby)

 

71

Attach

Mapped

24

40 0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

Slave A

 

72

Attach

Mapped

24

5 2 0 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Slave B

 

73

Attach

Mapped

4

2

0 0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150

 

74

Attach

Mapped

4

3

150

0

0

 

 

 

 

 

 

 

 

31007492

 

 

Device Addressing and Message Routing 23

Page 33
Image 33
Schneider Electric none manual From Routing Path, From Address Routing Method