MDT5N25 & MDT5N40

REFRIGERATION SERVICE: R-404A (HP62)

THIS ICE MACHINE USES HP62 REFRIGERANT AND POLYOLESTER COMPRESSOR OIL.

DO NOT USE MINERAL OIL IN THIS REFRIGERATION SYSTEM.

Pressure-Temperature Chart for HP62

VAPORVAPOR

￿R-404A is a “Near Azeotrope”, and therefore

TEMP. PRESSURE

liquid charging is required.

(DEG F)

(PSIG)

Weigh into the discharge side as much as

-20 . . . .

17

possible of the charge as liquid refrigerant.

-18 . . . .

18

Install a sight glass between the manifold

-16 . . . .

20

and the suction side hose. Carefully meter

-14 . . . .

21

liquid refrigerant into the suction side, using

-12 . . . .

23

the manifold valve to “flash off” the liquid

-10 . . . .

24

before it enters the ice machine. Do this until

-8 . . . .

26

the proper charge has been weighed into the

-6 . . . .

28

system.

-4 . . . .

29

￿When the system is serviced, a special liquid

-2 . . . .

31

0 . . . .

33

line dryer is required.

￿Polyolester oil absorbs water very easily, and

2 . . . .

35

4 . . . .

37

therefore when the system is opened for

6 . . . .

39

service, it must be re-sealed as soon as

8 . . . .

41

possible (15 minutes maximum).

10 . . . .

43

￿Special leak detection equipment is required to

12 . . . .

46

locate small refrigerant leaks. Usually a leak

14 . . . .

48

detector capable of detecting a Halogenated

16 . . . .

50

refrigerant or HFC-134A will work. Check with

18 . . . .

53

the leak detector manufacturer if in doubt.

20 . . . .

55

￿As with any other refrigerant, do NOT mix HP62

22 . . . .

58

with pressurized air when leak testing.

24 . . . .

60

 

26 . . . .

63

 

28 . . . .

66

 

30 . . . .

69

 

32 . . . .

72

 

34 . . . .

75

 

36 . . . .

78

 

38 . . . .

81

 

40 . . . .

85

 

42 . . . .

88

 

44 . . . .

91

 

46 . . . .

95

 

48 . . . .

99

 

50 . . . .

102

 

52 . . . .

106

 

54 . . . .

110

 

56 . . . .

114

 

58 . . . .

118

 

60 . . . .

123

 

62 . . . .

127

 

64 . . . .

132

 

66 . . . .

136

 

68 . . . .

141

May 2001

 

Page 30

 

TEMP.

PRESSURE

(DEG F)

(PSIG)

70 . .

. . . . 146

72 . .

. . . . 150

74 . .

. . . . 155

76 . .

. . . . 161

78 . .

. . . . 166

80 . .

. . . . 171

82 . .

. . . . 177

84 . .

. . . . 182

86 . .

. . . . 188

88 . .

. . . . 194

90 . .

. . . . 200

92 . .

. . . . 206

94 . .

. . . . 212

96 . .

. . . . 219

98 . .

. . . . 225

100. . . . . 232

102. . . . . 239

104. . . . . 246

106. . . . . 253

108. . . . . 260

110. . . . . 268

112. . . . . 275

114. . . . . 283

116. . . . . 291

118. . . . . 299

120. . . . . 307

122. . . . . 316

124. . . . . 324

126. . . . . 333

128. . . . . 342

130. . . . . 351

132. . . . . 360

134. . . . . 370

136. . . . . 379

138. . . . . 389

140. . . . . 399

142. . . . . 409

144. . . . . 420

146. . . . . 430

148. . . . . 441

150. . . . . 452

152. . . . . 464

154. . . . . 475

156. . . . . 487

158. . . . . 499