SERVICE DIAGNOSIS

 

 

 

Symptom

Possible Cause

Probable Correction

No water is vended

Check ice vending system, if no

Allow 2 minutes for system to

 

ice will dispense, check the splash

reset

 

panel cleaning switch

 

 

Check water supply

Restore water supply

 

Check inlet water valve

Replace valve if necessary

Makes ice, but with excessive

Mineral scale on auger or

Clean ice making system with

noise

evaporator

Scotsman Ice machine cleaner

 

Dry top bearing

Check top bearing for proper

 

 

lubrication

 

Dry auger drive gear motor

Check auger drive for proper

 

 

lubrication

 

Auger motor rotor bearings worn

Replace auger motor

 

Vibration from loose panel or

Locate vibrating component and

 

tubing

secure it.

 

Low water level

Check for air-lock in water line to

 

 

evaporator

 

 

Check for thermistor (water level

 

 

sensor) not shutting unit off when

 

 

there is lack of water.

Will not dispense ice

Vane turns & ice is available but

Check position of bin bottom. It

 

will not flow out of bin

must have its slot over the ice

 

 

dispense spout.

 

 

Check condition of bin walls. They

 

 

must be smooth and the bin must

 

 

be round. Replace if rough or out

 

 

of round.

Touch Free ice dispensing system

Check splash panel cleaning

Push to reset or wait 2 minutes for

does not operate water solenoid

switch

the board to reset itself

or dispense motor

 

 

Check for power to motor or

If power, check motor or solenoid.

 

solenoid

If no power, replace touch free

 

 

sensors

 

If new touch free sensors do not

Replace circuit board.

 

fix problem

 

No power to compressor contactor

Power light on, but Bin empty light

Check for ice between electric

and auger motor

not on

eyes or dirty eyes.

 

Power light not, bin empty light on,

Not enough water.

 

but Low water light on

 

 

Water too hot

 

 

 

Electric eyes failed

Replace photo electric eyes

 

Thermistor failed

Replace water level sensor

 

Circuit board failed

Replace circuit board

 

 

 